Ilnstalling the Cooktop
Remove grease jar(s) from beneath cooktop to avoid
breakage. Remove vent grille from cooktop's surface.
Using two people, position cooktop over counter top
opening, with power cable inserted through the opening.
Holding cooktop by side edges, lower it into counter-
top opening.
Replace jar(s) and vent grille.
i
Secure cooktop by tightening hold-down bolts in bot-
tom of the cooktop case. (Two bolts, one per side.)
Cooktop _
Case
/
1
_---C0untertop
-*_-- Hold Down Bolt
$ ep 8
Before Making Electrical Connections
Note to Electrician:
The power leads supplied with this appliance are U. L.
recognized for connection to large gauge household
wiring. The insulation of these leads is rated at tem-
peratures much higher than the temperature rating of
household wiring. The current carrying capacity of a
conductor is governed by the wire gauge and also the
temperature rating of the insulation around the wire.
Aluminum Wiring
WARNING: IMPROPER CONNECTION OF ALU-
MINUM HOUSE WIRING TO THE COPPER LEADS
CAN RESULT IN SERIOUS PROBLEMS.
Attach copper wires to aluminum wiring using special
connectors designed and U, L. listed for joining cop-
per to aluminum. Follow the connector manufacturer's
recommended procedure closely.
Making Electrical Connections
NOTE: The frame of this appliance is grounded to
neutral,
3-Conductor Branch Circuit
When connecting cooktop to a three-conductor
branch circuit, connect the red lead to the branch cir-
cuit red lead, and the black lead to the branch circuit
black lead. Connect the bare or green conductor and
the white lead of the cooktop to the branch circuit neu-
tral lead, which is white or gray.
3-Conductor Branch Circuit
Branch Circuit
120V AC
NEUTRAL
12OVAC
Red
White or
Gray
Black
(3O
(_'
Cooktop
Red
Bare or Green
Black
4-Conductor Branch Circuit
When connecting cooktop to a four-conductor branch
circuit, connect the red lead to the branch circuit red
lead, and the black lead to the branch circuit black
lead. Break connection between the cooktop white
lead and the bare or green conductor. Connect the
cooktop white lead to the branch circuit neutral lead,
which is white or gray. Ground the unit by connecting
the bare or green conductor of the cooktop to the
branch circuit bare or green lead (ground lead).
4-Conductor Branch Circuit
Branch Circuit Cooktop
Red _ Red
White or
120v AC Gray White
NEUTRAL _)
120V AC Black
Black (_)
Bare or Bare or
Green Green
GND
Electrical Requirements*
Model # Voltage Frequency KW
42825 120/240V 60HZ 8.0KW
42827 120/240V 60HZ 8.0KW
42725 120/240V 60HZ 8.0KW
42727 120/240V 60HZ 8.0KW
* For reference only, verify with products rating plate,