Loading ...
Loading ...
Loading ...
W415-1407 / 11.20.14
47
EN
REMOVE 4 SCREWS
BLOWER
MOUNTING PLATE
REMOVE 2 SCREWS
BURNER
BASE
11.3 BLOWER REPLACEMENT
Your comes equipped with a heat circulating blower. The
blower is pre-wired and is controlled by the remote control supplied with the
appliance.
Drywall dust will penetrate into the blower bearings, causing irreparable
damage. Care must be taken to prevent drywall dust from coming into contact
with the blower or its compartment. Any damage resulting from this condition
is not covered by the warranty policy.
A. Turn off the power to the appliance.
B. Turn off the gas valve.
C. Remove the glass door, logs, rear log supports, brick panels, air
de ector, burner assembly, panel support, panel support bracket.
D. The blower mounting plate can now be removed. Remove the four
screws that secure the plate to the rebox base.
E. The blower is secured to the rebox. Disconnect the wire
connectors before attempting to remove the blower from the
rebox.
F. Remove the two screws securing the blower and lift through
blower access opening.
NOTE: When re-installing the replacement blower, it will be necessary to
replace the gasket (W290-0104) on the blower mounting plate.
!
WARNING
BE CAREFUL NOT TO TEAR THE BURNER TRAIN GASKET. A REPLACEMENT GASKET CAN BE
ORDERED FROM YOUR LOCAL AUTHORIZED DEALER.
11.4 NIGHT LIGHT™ REPLACEMENT
This appliance comes equipped with our “Night Light”.
If in the event the lamp or lens needs to be replaced, follow these instructions.
Disconnect the two wire leads at the wire nut. Remove the four screws
securing the accent light assembly from the relief door. Disassemble the
light and the lamp now can be accessed
Note: Do not handle the lamp (bulb) with bare ngers, protect with
a clean dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel
parts only, as lamp and lens are special “high temperature” products.
When re-installing, ensure integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
When re-assembling the light assembly, care must be taken
with all gaskets.
“Light Leakage” from above the cast doors may
be noticed. The holes in the lamp housing are
necessary for ventilation and must not be covered.
GASKET
GLASS LENS
GASKET
SHEILD
RAIL
RAIL
WIRE NUT
COVER PLATE
RELIEF
DOOR