Specification
Domestic air conditioner
Note: the data are based on the conditions shown in the table below
htgnelgnipiPgnitaehgnilooc
Indoor: 27 DB/19 WB
Outdoor: 35 DB/24 WB
Indoor:20 DB
Outdoor: 7 DB/6 WB
5m
3 Sensors list
type Description Qty
3 in 1
itcetedrofdesustIrosnestneibmA edisroodtuofoerutarepmetgn
Suction sensor
Its used for detecting suction pipe temperature of compressor to
adjust gas flowing
1
Defrostin
g
sensor
Its used for controlling outdoor defrosting at heating mode
taeh-revofoesacnirosser
p
mocrofdesustI
rosnes
Discharging
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3
8
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type
R32
Refrigerant charge KG
1.45
Refrigerant control
EXV
Piping connections
(external diameter)
liquid mm
gas mm
drain mm
Heat insulation type Both liquid and Gas pipes
Max. piping Length m 25
Max. Level Difference m
Chargeless m 10
Amount of Additional Charge of Refrigerant g/m 20
International Protection degree
IP 24
12.7
17
circuit
15