INSTALLATION INFORMATION
CLEARANCES
www.ncertied.org
We recommend that our gas
hearth products be installed
and serviced by profes-
sionals who are certied in
the U.S. by the National
Fireplace Institute® (NFI) as
NFI Gas Specialists.
US Stove highly recommends your stove be
installed by a qualied NFI technician. To nd
the nearest qualied installer, go to:
https://ncertied.org,
To ensure a safe installation into the masonry or
factory-built replace, the following instructions
must be carefully followed:
1. Sidewall Clearances - Clearance from the
side of the replace opening to any adjacent
combustible wall should not be less than 7on
the right and left side.
2. Ceiling Clearances - The ceiling height should
not be less than 24” from the top of the replace
opening.
3. Mantel Clearances - Clearances from top of the
heater to mantel or mantel supports should not
be less than 20”.
NOTE: See the following sections for installation
options: Installation In A Solid-Fuel Burning
Fireplace and Installation With Optional Wooden
Mantel and Zero Clearance Installation.
WARNING:
ANY CHANGE TO THIS HEATER OR ITS
CONTROLS CAN BE DANGEROUS.
GAS CONNECTION
Check gas type. Use only the type of gas indicated
on the valve rating plate. If the type of gas listed on
the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for the proper model.
Always use an external regulator for all LP heaters
to reduce supply tank pressure to a maximum of 13”
W.C. This is in addition to regulator furnished with
heater.
WARNING:
CONNECTION DIRECTLY TO AN UNREGULATED
LP TANK CAN CAUSE AN EXPLOSION.
Normal gas connection is 3/8” N.P.T. made at the
left rear side of the appliance (facing front of the
appliance). NOTE: The connecting pipe must be
internally tinned copper tubing for use with natural
gas. Test for leaks using a solution of soap and
water after completing the connection. DO NOT
USE OPEN FLAME.
WARNING:
INSTALLATION AND REPAIRS SHOULD BE
PERFORMED BY A QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED
BEFORE USE AND AT LEAST ANNUALLY BY
A PROFESSIONAL SERVICE PERSON. MORE
FREQUENT CLEANING MAY BE REQUIRED
DUE TO EXCESSIVE LINT FROM CARPETING,
BEDDING. MATERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS OF
APPLIANCE BE KEPT CLEAN.
AFTER MARKET MOBILE HOME
INSTALLATION
NOTE: See “Producing Adequate Air For Combustion
And Ventilation” section of this manual.
THIS APPLIANCE MAY BE INSTALLED IN AN
AFTERMARKET*, PERMANENTLY LOCATED,
MANUFACTURED (MOBILE) HOME, WHERE NOT
PROHIBITED BY LOCAL CODES.
*After Market: Completion of sale, not for purpose of
resale from the manufacturer.
THIS APPLIANCE IS ONLY FOR USE WITH TYPE
OF GAS INDICATED ON RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH
OTHER GASES.
NOTE: For a mobile home installation follow the
“Installation” sections in this manual.
NOTE: See “Producing Adequate Air for Combustion
And Ventilation” section of this manual.
LOG SET PLACEMENT
Although your gas logs are very realistic in
appearance, it is not a real burning replace and
must not be used for burning rejected material.