17
may rest on standoffs on top of the rebox. When
the rebox is installed over carpeting, vinyl tile, or
any combustible material other than wood ooring,
it must be installed on a metal or wood panel
extending its full width and depth. Alternatively,
carpeting, vinyl tile, etc. may be removed beneath
the unit before installing.
INSTALLING FIREBOX (ZC)
This list of specic instructions will help you
make certain that every installation operation is
performed correctly. Complete installation steps in
the sequence shown.
LOCAL BUILDING CODES SHOULD BE CONSULTED
IN ALL CASES AS TO PARTICULAR REQUIREMENTS
CONCERNING INSTALLATION OF FACTORY BUILT
FIREPLACES. Select location for replace by taking
into consideration factors previously outlined in
“Choosing the Location.”
FRAMING FIREBOX
Width of the framed opening must be as shown
in the adjacent gures. The entire replace can be
elevated above the oor to achieve a raised hearth
effect. This can be done by adding a small platform
to achieve the desired height. NOTE: Wiring for
lower blower must be installed during the framing
stage. Insulation should be used in framing on the
back, sides, and top.
INSTALL FIREBOX
Install the rebox into the framed opening by
placing it directly in front of the opening and
sliding it into the proper position. Please follow the
wooden surround instructions (see Zero Clearance
standoff(s) Assembly” section of this manual).
LEVEL FIREBOX
Check the level of the rebox on the top edge of the
replace face. Shim if necessary.
COMBUSTIBLE MATERIALS MUST NOT BE
INSTALLED OVER OR TOUCH ANY BLACK-PAINTED
SURFACE. DO NOT BLOCK HEAT CIRCULATING AIR
OUTLETS. DOING SO MAY RESULT IN POTENTIAL
FIRE HAZARDS.
1. Sidewall Clearances: Clearances from the
side of the replace opening to any adjacent
combustible must be as shown in the gures
below.
2. Ceiling Clearances: There is a minimum
clearance from the top of the unit to the ceiling
that must be as shown in the gures below.
1
3-3/4”
25-1
/8”
SIDE VIEW
FRONT VIEW
24” MIN.
CLEARANCE
TO CEILING
FRAMING
HEADER
25-1/8”
WARNING:
INSTALLATION AND REPAIRS SHOULD BE
PERFORMED BY A QUALIFIED SERVICE
PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A PROFESSIONAL SERVICE
PERSON. MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIAL,
PET HAIR, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS OF
APPLIANCE BE KEPT CLEAN.
FINISHING YOUR FIREPLACE (ZC)
There is a wide variety of nishing material available
INSTALLATION