12
© 2020 United States Stove Company
OPERATING INSTRUCTIONS
release the control knob and it will pop back up.
The pilot should remain lit. If the pilot goes out,
repeat steps 1 through 9.
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to the “Off” position and call
your services technician or gas supplier.
IGNITOR ELECTP
THERMO-COUPLE
GENERATORPILOT
NAT
IGNITOR ELECTP
GENERATORPILOT
THERMO-COUPLE
LP
11. Turn the control knob counterclockwise to “On”.
12. If using the unit without a wall thermostat
place the Off/Manual (Off/Man) switch into the
manual position. If using a wall thermostat place
Auto/Off /Manual (Man) switch to the Auto” or
“Off” position and place thermostat to a setting
higher than the room’s temperature.
13. Close access cover door.
14. Turn on all electrical power to the appliance.
15. Your heater is equipped with a Hi & Lo control.
Turn clockwise for Low and counterclockwise
for High.
16. Close the access cover door.
TO TURN OFF GAS TO APPLIANCE
CAUTION:
DO NOT TRY TO ADJUST HEATING LEVELS BY
USING MANUAL SHUTOFF VALVE.
SHUTTING OFF UNIT
1. Open access cover door.
2. If equipped with a thermostat set to the lowest
setting.
3. Turn the control knob fully clockwise to the
“Off” position.
4. Turn off all electric power to the appliance if
service is to be performed.
5. Close access cover door
SHUTTING OFF BURNER ONLY (Pilot stays lit.)
1. Turn control knob clockwise to the “Pilot”
position.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING, FURNITURE,
GASOLINE AND OTHER LIQUIDS HAVING
FLAMMABLE VAPORS AWAY.
CAUTION:
DO NOT TRY TO ADJUST HEATING LEVELS BY
USING MANUAL SHUTOFF VALVE.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. REFER TO THE
OWNER’S INFORMATION MANUAL PROVIDED
WITH THIS APPLIANCE. INSTALLATION
AND SERVICE MUST BE PERFORMED BY A
QUALIFIED INSTALLER, SERVICE AGENCY OR
GAS SUPPLIER.