INSTALLATION INFORMATION
1
2
5
3
4
6
7
* LOG SET PART NUMBER 892464
GAS PRESSURE CHECK
Check inlet pressure to the burner to ensure that it
is as shown in the table below.
NOTE: The pressure checkpoint is located on the
right side of the valve facing burner, for SIT Millivolt.
The appliance and its main gas valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5kPa). The appliance
must be isolated from the gas supply piping system
by closing its equipment shut-off valve during any
pressure testing of gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
Gas Type Natural LP
Maximum Heat Input 33,000 33,000
Minimum Heat Input 23,000 23,000
Gas Inlet Pressure
Max 10.5” W.C. 13” W.C.
Min 5.0” W.C. 11” W.C.
Manifold Pressure
Max 3.5” W.C. 10.0” W.C.
Min 3.0” W.C. 8.2” W.C.
NOTE: On initial installation, it may be necessary to
bleed out the air in the gas lines. Do this by holding
the control knob and turning the knob to the “Pilot”
position for about 30 seconds. To check the regulator
pressure, remove the pressure tag plug at the left
side of the regulator facing the heater. The pressure
should be checked with the heater burning and the
control set on high. After measuring the pressure,
replace the pressure tap plug, ensuring that there
are no leaks.
For the purpose of minimum input adjustment.
WARNING:
THIS APPLIANCE IS EQUIPPED FOR (NATURAL
OR PROPANE) GAS. FIELD CONVERSION IS
NOT PERMITTED.
Solid fuels shall not be burned in the same replace
where an unvented room heater has been installed.
NOTE: The following label has been provided with
this appliance and must be read and then attached
to the oor of the replace or rebox area beneath
the appliance. Peel and stick the label. Make sure
the area is cleaned before attaching the label to it.
WARNING:
THIS SOLID-FUEL BURNING FIREPLACE OR
LISTED VENTLESS ENCLOSURE HAS BEEN
CONVERTED FOR USE WITH AN UNVENTED
FIREPLACE INSERT ONLY. A SOLID-FUEL
BURNING FIREPLACE CANNOT BE USED FOR
BURNING WOOD OR SOLID FUELS UNLESS ALL
ORIGINAL PARTS HAVE BEEN REPLACED AND
FIREPLACE RE-APPROVED BY THE AUTHORITY
HAVING JURISDICTION. A VENTLESS FIREBOX
ENCLOSURE CANNOT BE USED WITH AN
UNVENTED GAS LOG UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND VENTLESS
FIREBOX ENCLOSURE REAPPROVED BY
AUTHORITY HAVING JURISDICTION.