Cut away suction line at the above locations.
Drill a ½” hole downward into machine
compartment.
Extend new assembly through the hole.
Make sure ends are capped.
Install vibration isolator on heat exchanger
assembly behind evaporator.
Size and cut the suction tube extension to
connect the compressor to the suction line.
Top of machine compartment
Interior back wall