Loading ...
Loading ...
Loading ...
20306741
37
BLDV7 Series Gas Fireplace
OPERATING INSTRUCTIONS - SIGNATURE COMMAND
Fault LED Indication
Conversion Cover Missing One RED (1 time)
Spark Fail Two RED (1 time)
No Sensor Signal Three RED (1 time)
Pilot Lockout - trial One GREEN, every 2 sec.
(until manual reset)
PilotLockout-ameloss One RED-GREEN, every 2
sec. (until manual reset)
Low Battery One RED, every 10s
(continuously)
No or Low Thermopile Power Two RED, every 10s
(continuously)
Learning GREEN Flashes, every
1 sec. (for 10 sec.)
AC Power On GREEN solid
Pressure Switch Failure
(Power Vent Only)
One RED every 2 sec. (until
manual reset)
FUNCTIONS/OPERATION
Turning on the replace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center or turn
on wall switch. Pilot will light and burner will come on
High setting or last memory setting (See Turning Off
Fireplace below). For memory feature.
Pilot Safety Lockout Function
1. If the pilot doesn’t light after sparking for 30 seconds,
pilot trial lockout happens. The LED on the Command
CenterashesGreenonceevery2seconds,untilreset.
2. If the pilot ame is lost during normaloperation, the
system will try three (3) times to relight after three (3)
failures,amelosslockouthappens.TheLEDonthe
Command Center ashes Red-Green once every 2
seconds, until reset.
3. Turning the master switch on the Command Center to
the off position, then ON again will reset the system.
Flame Height Control
1. Press the ON button (on the Command Center) once
toturnonthemainburnerwithmaximumameheight.
2. PresstheOFFbuttontodecreaseameheight.Therst
Function Operation
Power Up Flip the master switch to the ON ("–") position
to power up the system
Fireplace ON Press the ON s button on the Command
Center or turn on wall switch to turn the
replaceon
Fireplace
OFF
Flip the master switch to the OFF ("o")
position OR press the OFF t button 3 times
OR for Memory Off, hold the OFF t button 3
seconds, or turn off wall switch
Flame Height
Up
Press the ON s button once to turn on the
replacewithmaximumameheight
Flame Height
Down
Press the OFF tbuttontolowertheame
height to Medium and Low
twopresseswilldecreasetheameheighttomedium
and low.
3. The third press on OFF will turn off the main burner. In
standingpilotconguration,thepilotwillstay;ininter-
mittentpilotconguration,thepilotwillbeshutoff.
Turning the Fireplace Off
Therearethreewaystoturnthereplaceoff.
1. Flip the master switch to the off (“O”) position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settingsbeforeturningoff.Thenexttimethereplaceis
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those
new settings.
Self Diagnostics Chart
The Command Center has a self-diagnostic LED enabling
you to troubleshoot problems and potentially avoid a
service call. Please refer to the charts below for indicator
reference.
Loading ...
Loading ...
Loading ...