Loading ...
Loading ...
Loading ...
20306741
26
BLDV7 Series Gas Fireplace
SIGNATURE COMMAND INSTALLATION
Figure 34 -
Signature Command Valve
FP1909a
signature command valve
alternate view
8/08
Pressure Inlet
Pilot Adjust-
ment Screw
Pressure Outlet
CHECK THE GAS TYPE AND PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
isdifferentfromthereplace,STOP! Do not install the
appliance. Contact your dealer immediately.
2. Toeaseinstallation,a24"(610mm)exlinewithmanual
shut-off valve has been provided with on this appliance.
Install and attach 1/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
replaceforleaks.Useasolutionof50/50waterand
soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 34. After taking pressure reading, be sure and
turncapturedscrewclockwisermlytoreseal.Donot
over torque. Check test points for gas leaks.
ELECTRICAL WIRING
General
1. This replaceis equippedwith theSignature Control
valve which operates on 6 volts. The 6 volt DC adapter
plugsintothereplacejunctionboxA/Cpowersupply.
Four (4) “AA” batteries are used for back up during
power outages.
2. The Signature Command System can also be operated
without A/C power. The system can run on four (4) “AA”
batteries for approximately six (6) months under normal
use.
3. A/C power must be used to power the A/C module,
blowers,lightsandAUXaccessoriesifusedwiththis
replace.
Optional Accessory Requirements
1. This replace may be used with a wall switch, wall
mounted thermostat and/or Signature Command wire-
less controls.
2. The command center control may be mounted on the
wall with the use of the SCSWEK 15ft. wall mount
extension kit.
CAUTION
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and
dangerous operation.
WARNING
Electrical connections should only be performed by a
qualied,licensedelectrician.Mainpowermustbeoff
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest edition)
and Canadian Electrical Code, CSA C22.1.
WARNING
Donotuseopenametocheckforgasleaks.
Loading ...
Loading ...
Loading ...