Loading ...
Loading ...
Loading ...
34
E
Cleaning and Maintenance
Charcoal Filter
Charcoal Filter is used for Non-vented, recirculated installation.
The filter should be changed every 6 to 12 months depending on
use.
1. Disconnect power to the oven at the circuit breaker panel or by
unplugging.
2. Remove 2 screws that secure louver.
3. Remove louver by gently moving louver and pull away from unit.
4. Remove 2 screws that secure the sensor duct cover.
5. Remove the sensor duct cover.
6. Remove old charcoal filter (if one is installed).
7. Slide new charcoal filter into position on the support tabs.
8. Reattach sensor duct cover and secure with 2 screws.
9. Push louver back into place and replace the 2 screws to secure
louver.
Microwave Oven light
Remove the louver per instructions 1-3 on CHARCOAL FILTER
section (page 34) and charcoal filter, if used.
4. Slide the light cover forward and lift up.
5. Remove old light bulb and replace only with a 20 watt bulb
available at most hardware stores or lighting centers. DO NOT
USE A BULB LARGER THAN 30 WATTS.
6. Replace the microwave oven light cover and charcoal filter, if
used; push louver back in place and replace the louver mounting
screws.
CAUTION
Light cover may become very hot.
Do not touch glass when light is on.
Sensor duct cover
Charcoal filter
Product CareProduct Care
Louver
Oven light
Charcoal filter
Screw
Loading ...
Loading ...
Loading ...