Napoleon HD81NT-1 High Definition 81

User Manual - Page 45

For HD81NT-1.

PDF File Manual, 112 pages, Read Online | Download pdf file

HD81NT-1 photo
Loading ...
Loading ...
Loading ...
EN
W415-2362 / A / 10.25.19
45
maintenance
NOTE: A new gasket will be required, when
re-installing the access panel (see “HD81-1
OVERVIEW” in the “REPLACEMENTS” section).
Remove one of the main doors, see “DOOR REMOVAL
/ INSTALLATION” section. Remove either the optional
brick or porcelain panel from the side
where the control box is located. Remove the eight
screws from the access panel.
10.2 control access
10.2.1 inner access panel
The valve on this appliance is piped with three fl ex connectors (one inlet, two outlets). It can be removed and
pulled forward for service.
A. Remove the optional panels.
B. Remove the air manifold, refer to Figure 1.
C. Remove inner access panel, see “INNER ACCESS PANEL” section.
D. Remove the wing nut and pivot the valve out from the slot at the bottom of the valve, refer to Figure 2.
E. Slowly pull the valve through the control door being careful not to kink the gas lines or wires.
Disconnect fl ex connectors.
F. Replace all components before returning the appliance to service.
G. Check for gas leaks by brushing on a soap and water solution.
10.3 valve removal
ACCESS
PANEL
VALVE
ACCESS
HOLE
CONTROL
BOX
WING
NUT
VALVE
FIGURE 1 FIGURE 2