framing
IMPORTANT: This appliance requires a minimum inside enclosure height of 84” (213cm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the air.
4.4 minimum clearance to combustible enclosures
84"
213cm *
MINIMUM
ENCLOSURE
HEIGHT
50 9/16"
128.4cm
MINIMUM
33 7/16"
MINIMUM
66 7/8"
1.7m
MINIMUM
PLUS RISE *
2"
50.8mm
11 5/8"
29.5cm
MINIMUM **
MINIMUM
7 5/8"
194mm
COMBUSTIBLE
MATERIAL
TOP OF ENCLOSURE
BRICK
STEEL STUD
FRAMING
TOP OF
APPLIANCE
OPENING
0” (0mm) IF NON-
COMBUSTIBLE FINISHING
IS USED SUCH AS BRICK
AND STONE
84.9cm
2"
50.8mm
* Refer to “VENTING” section.
** NOTE: Within the appliance enclosure a 3” (76.2mm) clearance between the vertical vent run and
the combustible materials on the front facing of the enclosure is required. Similarly, a 11 5/8” (29.5cm)
clearance to combustible materials from the top of the horizontal vent run is required. All other
clearances within the enclosure, including where the vent pipe exits the enclosure are subject to 2”
(50.8mm) for horizontal and 1” (25.4mm) for vertical.
!
WARNING
Risk of fi re!
The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite,
etc. provided that these materials do not cover the appliance opening.