9. Installationandoperationmanualfordemandresponse(DRED)
9.4. Demandresponsemode
ThisunithasdemandresponsecapabilitywhichiscompliantwithAS/NZS4755.3.1:2012.
To activate this function, you need to make a contract with remote agents such as electric supply company, then this unit should be connected to Demand response enabling
devise (DRED). For further information, consult your dealer.
Demandresponserepresentstheautomatedalterationofanelectricalproduct’snormalmodeofoperationinresponsetoaninitiatingsignaloriginatingfromordened
by a remote agent.
This unit supports 3 Demand Response Modes (DRMs).
DRM Description of operation in this mode
DRM 1
Compressor off
The air conditioner does not perform cooling or heating operation during the demand response event.
DRM 2
The air conditioner continues to perform cooling or heating operation during the demand response event, but the electrical energy consumed by the
air conditioner in a half hour period is not more than 50% of the total electrical energy that would be consumed if operating at the rated capacity in a
half hour period.
DRM 3
The air conditioner continues to perform cooling or heating operation during the demand response event, but the electrical energy consumed by the
air conditioner in a half hour period is not more than 75% of the total electrical energy that would be consumed if operating at the rated capacity in a
half hour period.
Note:
• DRMisautomaticallyactivatedorreleasedaccordingtothesignalsfromDRED.
DRM cannot be invalidated or changed manually.
• YoumightfeelthisunitdoesnotsufcientlyperformcoolingorheatingoperationduringDRM.
• OperationsettingscanbechangedasusualwiththeremotecontrollerduringDRM.
However, you might not feel cool or warm enough as DRM is prioritized.
• WhenthisunitreceivestheDRM1signal,theresponsetimeuntiltheDRM1modeisactivatediswithin60sec.
However, if the maintenance and safety modes are activated, those modes have priority.
• TheterminalblockfortheDREDsatisestheELVrequirements.