21
GB
1. Useaseparatepowersupplyfortheoutdoorunitandindoorunit.
2. Bearinmindambientconditions(ambienttemperature,directsunlight,rainwater,etc.)whenproceedingwiththewiringandconnections.
3. Thewiresizeistheminimumvalueformetalconduitwiring.Thepowercordsizeshouldbe1rankthickerconsiderationofvoltagedrops.
Makesurethepower-supplyvoltagedoesnotdropmorethan10%.
4. Specicwiringrequirementsshouldadheretothewiringregulationsoftheregion.
5. Powersupplycordsofpartsofappliancesforoutdooruseshallnotbelighterthanpolychloroprenesheathedexiblecord(design60245IEC57).Forexample,
usewiringsuchasYZW.
6. Installanearthlongerthanothercables.
Sample chart
6. Electricalwork
Warning:
• Please turn off the main power supply when servicing.And do not touch the B1, B2 terminals when the power is energized. If isolator should be used
betweenoutdoorunitandbranchbox/indoorunitandbranchbox,pleaseuse2-poletype.
(Pleaserefertogurebelow.)
Caution:
Afterusingtheisolator,besuretoturnoffandonthemainpowersupplytoresetthesystem.Otherwise,theoutdoorunitmaynotbeabletodetectthebranch
box(es)orindoorunits.
Besuretoconnecttheoutdoor-branchbox/indoor-branchboxconnectingcablesdirectlytotheunits(nointermediateconnections).
Intermediateconnectionscanlead to communication errors if water entersthecablesandcauses insufcient insulation to ground or a poorelectricalcontactat the
intermediate connection point.
(If an intermediate connection is necessary, be sure to take measures to prevent water from entering the cables.)
B1
B2
L
N
Outdoor unit
2 poles isolator (Switch)
Branch box
Warning:
• Besuretousespeciedwirestoconnectsothatnoexternalforceisimpartedtoterminalconnections.Ifconnectionsarenotxedrmly,itmaycauseheat-
ingorre.
• Besuretousetheappropriatetypeofovercurrentprotectionswitch.Notethatgeneratedovercurrentmayincludesomeamountofdirectcurrent.
• Besuretoattachtheterminalblockcovers/paneloftheoutdoorunitsecurely.
Ifitisnotattachedcorrectly,ifcouldresultinareoranelectricshockduetodust,water.etc.
Caution:
• Becarefulnottomakemis-wiring.
• Firmlytightentheterminalscrewstopreventthemfromloosening.
• Aftertightening,pullthewireslightlytoconrmthattheynotmove.
• Iftheconnectingwireisincorrectlyconnectedtotheterminalblock,theunitdoesnotoperatenormally.
• Someinstallationsitemayrequireattachmentofanearthleakagebreaker.Ifnoearthleakagebreakerisinstalled,itmay
causeanelectricshock.
• Donotuseanythingotherthanbreakerandfusewithcorrectcapacity.Usingfuseandwireorcopperwirewithtoolarge
capacitymaycauseamalfunctionofunitorre.
IMPORTANT
Makesurethatthecurrentleakagebreakerisonecompatiblewithhigherharmonics.
Alwaysuseacurrentleakagebreakerthatiscompatiblewithhigherharmonicsasthisunitisequippedwithaninverter.
Theuseofaninadequatebreakercancausetheincorrectoperationofinverter.
Neversplicethepowercableortheindoor-outdoor-branchboxconnectioncable,otherwiseitmayresultinasmoke,areorcommunicationfailure.
<Exampleof“F2”calculation>
Condition PEFY-VMS1 × 4 + PEFY-VMA × 1, C = 8 (refer to right sample chart)
F2=19.8×4/8+38×1/8
= 14.65
*3 Current sensitivity is calculated using the following formula.
G1={V2×(QuantityofType1)}+{V2×(QuantityofType2)}+···+{V2×(QuantityofType16)}
+{V3×(Wirelength[km])}
G1 Current sensitivity
30 or less 30 mA 0.1 sec or less
100 or less 100 mA 0.1 sec or less
Wire thickness V3
1.5 mm
2
48
2.5 mm
2
56
4.0 mm
2
66
6000
600
60
10
1
1 2 3 4 6 8
C
10 20
Rated Tripping current (x)
SAMPLE
0.1
0.01
TrippingTime[s]
Connection details
Lead wire
Terminal
block
Loosen terminal screw.
RG79Y960H01.indb 21 2018/02/09 14:31:10