Insure that the copper ground strap IS CONNECTED
between the middle post of the main terminal
connection block and the range chassis.
The middle wire of the service cord MUST connect to
the neutral (middle) post of the main terminal block.
The other two wires of the service cord connect to the
outside posts of the main terminal connection block.
Polarity is unimportant.
Position strain relief with flanges on top of conduit plate
as shown and secure to service cord.
,
.
.
The range conduit must be routed and properly
connected to an approved electrical junction box
behind the range.
The red and black wires from the range conduit must
respectively connect to the red and black service wires.
An approved wire connector must be used.
Both the white wire and the uninsulated (bare) wire
from the conduit should connect to the white service
wire as shown. The bare wire is the range chassis
ground.
RED--_
WHIT(--_
BLACK ---3k_
GROUND STRAP _ _'_L
(CONNECTE0 AT
FACTORY)
STRAI N-----"
REL I EF
MA_IN T£RMINAL
CONNECTION BLOCK
MIDDLE WIRE OF
SERVICE COR0
I CONDUIT
PLATE
1
CONDUIT
PLATE I J
I I
REMOVE KNOCKOU 'i_
SERVICE CORD (PIGTAIL) USE.
L OUTLET MOUNTED
FLUSH IO WALL
ALTERNATEINSTALLATION
OUTLET TO BE ROTATED AS
SHOWN IF NOT FLUSH TO WALL
FIGURE 8
NORMAL - 3 WIRE PLUG
NOTE: ROUTE RANGE CONDUIT SO THAT IT
CONTAINS NO KINKS AND DOES NOT
INTERFERE WITH INSTALLATION OF UNIT.
/I (RE)}
NEUTRAL
{BLACK)
CIRCUIT
{POWER SUI_Y)
RANGEGROUM:IEDTHROUGHNEUTRAL CONDUCTOR.
FIGURE 9
NORMAL - 3 WIRE CONDUIT