Loading ...
Loading ...
Loading ...
37





This range comes from the factory set for use on natural
gas, but it is convertible for use on LP gas. If you decide
to use this range on LP gas, conversion must be made by
a qualified LP installer before attempting to operate the
range.
For proper operation, the inlet pressure to the regulator
should be at least 1” W.C. above the operating manifold
pressure but must not exceed 14” W.C.
The pressure regulator located at the inlet of the range
manifold must remain in the supply line regardless of
whether natural or LP gas is being used. When checking
for proper operation of the regulator, the inlet pressure
must be at least 1” greater than the operating manifold
pressure.
A flexible metal appliance connector used to connect the
range to the gas supply line should have an I.D. of ½
and be 5 feet in length for ease of installation. In Canada,
flexible connectors must be single wall metal connectors no
longer than 6 feet in length.





Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector is recommended unless local codes
require a hard-piped connection.
Never use an old connector when installing a new range.
If the hard piping method is used, you must carefully align
the pipe; the range cannot be moved after the connection
is made.
To prevent gas leaks, put pipe-joint compound on, or wrap
pipe-thread tape with Teflon* around, all male (external)
pipe threads.
A. Install a manual gas line shut-off valve in the gas line
in an easily accessed location outside of the range.
Make sure everyone operating the range knows where
and how to shut off the gas supply to the range.
B. Install male 1/2 flare union adapter to the 1/2 NPT
internal thread at inlet of regulator. Use a backup wrench
on the regulator fitting to avoid damage.
B. When installing the range from the front, remove the 90°
elbow for easier installation.
C. Install male 1/2 or 3/4 flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care
to back up the shut-off valve to keep it from turning.
D. Connect flexible metal appliance connector to
the adapter on the range. Position range to permit
connection at the shut-off valve.
E. When all connections have been made, make sure
all range controls are in the off position and turn on
the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.
When using test pressures greater than 1/2 psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of 1/2
psig or less to test the gas supply system, simply isolate
the range from the gas supply system by closing the
individual shut-off valve.
*Teflon: Registered trademark of DuPont
 DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.







Your range, like many other household items, is heavy and
can settle into soft floor coverings such as cushioned vinyl
or carpeting. Use care when moving the range on this type
of flooring. It is recommended that the following simple and
inexpensive instructions be followed to protect your floor.
The range should be installed on a sheet of plywood
(or similar material). When the floor covering ends at
the front of the range, the area that the range will rest
on should be built up with plywood to the same level
or higher than the floor covering.
This will allow the range to be moved for cleaning
or servicing. Also, make sure your floor covering will
withstand 18F. (See the Installation Safety Instructions
section.)
Make sure the wall coverings around your range can
withstand the heat generated (up to 200°F) by the range.
(See the Installation Safety Instructions section.)
Loading ...
Loading ...
Loading ...