User Manual Honeywell RTH221B1039/U1 1-Week Programmable Thermostat

Honeywell RTH221B1039/U1 1-Week Programmable Thermostat - Use Manual - Use Guide PDF.
Documents: Go to download!
User Manual
  • User Manual - (English, French)
  • RTH221 Programmable Thermostat - (English)
Specification


User Manual Honeywell RTH221B1039/U1 1-Week Programmable Thermostat

Installation

1. Turn Off Power to Heating/Cooling System

2. Remove Old Thermostat

Remove old thermostat but leave wallplate with wires attached.

If you have an older thermostat with a sealed mercury tube, turn to page for proper disposal instructions.

3. Label Wires with Tags

Label the wires using the supplied wire labels as you disconnect them.

4. Separate Wallplate from New Thermostat

Remove wallplate from the new thermostat and mount onto wall.

5. Mount Wallplate

Mount the new wallplate using the included screws and anchors.

Drill 3/16-in. holes for drywall

Drill 3/32-in. holes for plaster

6. Connect Wires

Simply match wire labels.

If labels do not match letters on the thermostat, check “Alternate Wiring” on page 6 and connect to terminal as shown here (see notes, below).

Thermostat does not work on Heat Pumps with auxiliary/backup heat.

We are here to help. Call 1-800-468-1502 for wiring assistance.

Alternate Wiring

  1. If wires will be connected to both R and Rc terminals, remove metal jumper.
  2. Do not use C or X. Wrap bare end of wire with electrical tape.
  3. If you have a heat pump without auxiliary/backup heat connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap bare end of wire with electrical tape.
  4. Place a jumper (piece of wire) between Y and W if you are using a heat pump without auxiliary/backup heat.

7. Install Batteries

8. Set fan operation switch

Move the switch to the proper setting:

Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position (for systems that control the fan in a call for heat).

Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)

9. Install Thermostat onto Wallplate

Install thermostat onto the wallplate on the wall.

10. Turn Power Back On

Turn the power back on to the heating/cooling system.

11. If your system type is...

If your system type is:

  • Single Stage Heat and Cool
  • Heat Only or Cool Only

Congratulations, you’re done!

If your system type is:

  • Heat pump
  • High efficiency furnace
  • Hot water
  • Electric furnace
  • Gas/oil steam
  • Gravity system

Continue with Advanced Installation to match your thermostat to your system type.

If you are not sure of your system type or if you have other questions, call us toll-free at 1-800-468-1502.

This thermostat works on 24 volt or 750 mV systems. It will NOT work on multi- stage conventional systems.

Advanced Installation

Enter System Setup

To enter system setup, press and hold both the and buttons until the display changes (approximately 5 seconds).

Changing Settings

  1. Press the or button to change the setting.
  2. Press the and buttons simultaneously for one second to advance to the next function.
  3. Press the RUN button to exit and save settings.

NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu.

About your new thermostat

Your new thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.

  • Backlit display on RTH2300
  • Displays ambient (measured) temperature at all times
  • One-touch access to setpoint temperature
  • Preset program settings
  • Temporary and permanent override of schedule
  • Built-in compressor protection

Thermostat controls

Display screen

Programming and operation

Set the time and day

  1. Press the SET button, then press or to set the clock time.
  2. Press the SET button, then press or to select the day of the week.
  3. Press RUN to save & exit.

NOTE: If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day.

Program Schedule

You can program four time periods each day, with different settings for weekdays and weekends. We recommend the pre-set settings (shown in the table below), since they can reduce your heating/cooling expenses.

Wake - Set to the time you awaken and the temperature you want during the morning, until you leave for the day.
Leave - Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).
Return - Set to the time you return home and the temperature you want during the evening, until bedtime.
Sleep - Set to the time you go to bed and the temperature you want overnight usually an energy-saving level).

NOTE: Leave and Return periods can be canceled on weekends.

To adjust program schedules (RTH221)

  1. Press SET until Set Schedule is displayed.
  2. Press or to set your Wake time (Mo-Su), then press SET.
  3. Press or to set the temperature for this time period, then press SET.
  4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each time period.
  5. Press RUN to save & exit.

NOTE: Make sure the thermostat is set to the system you want to program (Heat or Cool).

Program schedule override (temporary)

Press or to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period.

"Temporary” will appear on the display and the current program period will flash.

The new temperature will be maintained only until the next programmed time period begins (see page 11).

To cancel the temporary setting at any time, press RUN.

NOTE: Make sure the thermostat is set to the system you want to control heat or cool).

Program schedule override (permanent)

Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods.

The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed.

Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN to cancel “Hold” and resume the program schedule.

NOTE: Make sure the thermostat is set to the system you want to control heat or cool).

Built-in compressor protection

This feature helps prevent damage to the compressor in your air conditioning or heat pump system.

Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting.

During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.

Battery replacement

Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for 60 days before the batteries are depleted.

Replace batteries once a year, or when you will be away for more than a month.

Most settings are stored in non- volatile (permanent) memory. Only the clock and the day must be set after you replace the batteries.

Pull at bottom to remove thermostat from wallplate.

Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain activated even when batteries are removed.

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank

  • Make sure fresh AAA alkaline batteries are correctly installed.

Heating or cooling system does not respond

  • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature.
  • Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
  • Wait 5 minutes for the system to respond.

Temperature settings do not change

Make sure heating and cooling temperatures are set to acceptable ranges:

  • Heat: 40° to 90°F (4.5° to 32°C).
  • Cool: 50° to 99°F (10° to 37°C).

" Cool On” or "Heat On” is flashing

  • Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.

" Heat On” is not displayed

  • Set the System switch to Heat, and set the temperature level above the current room temperature.

"Cool On” is not displayed

  • Set the System switch to Cool, and set the temperature level below the current room temperature.

1 year limited warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).

If the product is defective,

i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or

ii) call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.



See other models: YTH6320R1001/U HUL570B TH3210D1004/U TH6320ZW2003/U TH1100DV1000/U

Honeywell RTH221B1039/U1 | Series: RTH2300/RTH221 Series | File type: PDF | Filename: Honeywell RTH221B1039:U1 1-Week Programmable Thermostat .pdf | Size: 978.32 KB | Language: English, French | Other documents: 2 files.

Download User Manual

Specs Sheet

  • Program Modes: 1 Week
  • Energy Star Certified: Yes
  • Special Feature : Low Battery Indicator, Clock Display, Low Voltage, Programmable
  • Number of Batteries: 2 AA batteries required.
  • Product Height: 3.75 in
  • Product Width: 5.75 in
  • Product Depth: 1.25 in
  • Product Dimensions: 1"D x 4.75"W x 3.5"H
  • Item Weight: 0.3 Pounds
  • Controller Type: Hand Control
  • Control Type: Button Control
  • Control Method: Touch
  • Connectivity Technology: Non-connected
  • Power Source: Battery Powered
  • Voltage: 24 Volts
  • Material: Plastic
  • Display Type: LCD

Product Infomation and Reviews - RTH221B1039/U1 photo

RTH221B1039 U1 Photo

Honeywell in United States

1 (877) 841-2840

Honeywell RTH221B1039/U1 Questions and Answers

Find answers or Ask a question.
  • Total questions: 5
  • Questions unAnswered : 5

#1 Do you need assistance?
Call 1-800-468-1502 for wiring assistance - it is Honeywell Customer Service phone number.