Loading ...
Loading ...
Loading ...
41
11. Technical Data
This cooker is designed for use on natural gas but can be converted to LP (Propane X (2.54 kPa)).
A conversion kit from Natural Gas to Propane is supplied with the cooker.
Installer: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity and on rear of the appliance.
COUNTRY OF DESTINATION: Australia
Connections
Gas (Rp½ at right rear) Electric
Natural Gas 1 kPa 240 V 50 Hz
Propane 2.54 kPa
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 905 mm maximum 925 mm
Overall width
900 mm; see ‘Positioning of Cooker.
Overall depth
607 mm (619mm including spacer) to hob front;
649mm (661mm including spacer) over handles
Minimum space above hotplate
800 mm
Ratings
Oven
Full Divided
Fan element 3.31 kW 1.65 kW
Top element 3.49 kW 1.75 kW
Browning element 2.11 kW 1.06 kW
Bottom element 1.38 kW 0.69 kW
Natural Gas 1 kPa Propane X 2.54 kPa
Hotplate Input
Injector
Bypass
marking
Input
Injector
Bypass
marking
Marking Size Ø Marking Size Ø
Wok burner 15.2 Mjh
-1
Internal 112 1.12 mm
90 15 Mjh
-1
Internal 66 0.67 mm
54
External 164 1.65 mm External 91 0.87 mm
Large burner 12.3 Mjh
-1
165 1.65 mm 80 12 Mjh
-1
89 0.96 mm 41
Medium burners 6.2 Mjh
-1
115 1.15 mm 56 6.2 Mjh
-1
67 0.68 mm 33
Small burner 3.7 Mjh
-1
92 0.92 mm 48 3.3 Mjh
-1
48 0.50 mm 25
Maximum total electric load 240 V: 3.9 kW (including oven fans, lights, etc.)
Loading ...