Loading ...
Loading ...
Loading ...
27INSTALLATION
ENGLISH
Check the Duct Condition
If the Flow Sense™ LED is turned on, check the
exhaust system for restrictions and damage. Repair
or replace the exhaust system as needed.
NOTE
When the dryer is rst installed, this test should be
performed to alert you to any existing problems with
the exhaust duct in your home. However, since the
test performed during normal operation provides
more accurate information on the condition of the
exhaust duct than the installation test, the number
of bars displayed during the two tests may not be
the same.
Do not interrupt the test cycle, as this could result in
inaccurate results.
Even if no bars are displayed during the test cycle,
some restrictions may still be present in the exhaust
system. Refer to the Venting the Dryer section
of this manual for complete exhaust system and
venting requirements.
Error Code
Check the error code before you call for service.
Error
Code
Possible
Causes
Solutions
tE1 or
tE2
Temperature
sensor failure.
Turn off the dryer and call
for service.
HS
Humidity sensor
failure.
Turn off the dryer and call
for service.
PS,
PF, or
nP
Electric dryer
power cord is
not connected
correctly, or
house power
supply is
incorrect.
Check the power supply
or the connection of
the power cord to the
terminal block. Refer to
the Connecting Electric
Dryers section of this
manual for complete
instructions.
House fuse is
blown, circuit
breaker has
tripped, or
power outage
has occurred.
Reset circuit breaker
or replace fuse. Do
not increase the fuse
capacity.
If the problem is a
circuit overload, have it
corrected by a qualied
electrician.
Restricted or Blocked Airow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Lint buildup or blockage
Make sure the ductwork is not crushed or restricted.
Crushed or damaged
exhaust
Loading ...
Loading ...
Loading ...