User Manual Thermador T18IF900SP 18-Inch Built-in Panel Ready Freezer Column

Thermador T18IF900SP 18-Inch Built-in Panel Ready Freezer Column - Use Manual - Use Guide PDF.
Documents: Go to donwload!
  • Owner's manual - (English, French, Spanish)

USER MANUAL Freezer Thermador T18IF900SP

Table of contents

  • Important safety instructions
  • Intended use
  • Environmental protection
  • Installation and connection
  • Getting to know your appliance
  • Operating the appliance
  • Alarm
  • Freezer compartment
  • Defrosting
  • Cleaning
  • Noises
  • Lighting
  • Faults – what to do?
  • Customer service

Installation and connection

Installation location

  • The weight of the appliance may be up to 460 kg depending on the model. The base must be sufficiently stable and should not give. If necessary, reinforce the floor.

Check built-in cut-out

The cut-out must fulfill these criteria:

  • Anti-tilt bracket must be fitted
  • Cut-out depth min. 24” (610 mm), for flush installation 25” (635 mm)
  • rectangular
  • stable – the side panels and the top must be min. 5/8" (16 mm) thick and securely attached to the floor or wall
  • Depth of shortest side panels min. 4” (100 mm)

Side-by-side installation

  • Observe the specifications in the installation instructions for a side-by-side installation.
  • If a partition wall is required between the appliances it must be at least 5/8" (16 mm) wide.

Before using for the first time

  1. Remove information material, adhesive tape and protective foil.
  2. Clean the appliance.

Water connection

  • Installation and connection of the appliance must be carried out by authorized technicians according to the installation instructions supplied.
  • To avoid damage to the appliance and to ensure its proper functioning, it should only be connected to a drinking water system.
  • To avoid water damage, a shut-off valve must be installed.

Water pressure of drinking water system

Note: If the water pressure is too low, this will impair the relevant functions of the appliance.

  • Min. 0.2 Mpa (2 bar / 29 psi)
  • Max. 0.8 Mpa (8 bar / 116 psi)

Electrical connection

Note: You can connect the appliance to mainscontrolled and sine-controlled inverters.

Mains-controlled inverters are used for photovoltaic systems which are connected directly to the national grid. Sine-controlled inverters must be used for isolated applications. Isolated applications, e.g. on ships or in mountain lodges, are not directly connected to the national grid.

  1. After installing the appliance, wait at least 1 hour before connecting it to prevent damaging the compressor.
  2. Check that the outlet was installed according to the regulations and complies with the requirements.
  3. Connect the appliance to an outlet near the appliance. The outlet must also be freely accessible following installation of the appliance.

Cleaning

CAUTION

AVOID DAMAGING THE APPLIANCE AND THE EQUIPMENT.

  • Do not use abrasive, chloride-based or acidic cleaning agents or solvents.
  • Do not use scouring or abrasive sponges. The metallic surfaces may corrode. 
  • Never clean the shelves or bins in the dishwasher. The parts may become deformed.

Cleaning the display

  • The change in temperature and humidity can cause the controls to steam up.
  • Switch the clean lock on before cleaning.
  • Use a clean micro-fiber cloth for cleaning.

Cleaning the appliance interior

Proceed as follows:

  1. Press the main On/Off switch.
  2. Take out food and store in a cool location. Place ice pack (if available) on the food.
  3. Clean the appliance with a soft cloth, lukewarm water and a little pH-neutral washing-up liquid.
  4. Wipe door seal with clear water and dry thoroughly with a cloth.
  5. Switch appliance back on and put in food.

Care instructions for stainless steel surfaces

  • When taking care of and cleaning stainless steel surfaces, use only cleaning agents suitable for stainless steel and a stainless steel cleaning cloth.
  • You can purchase a suitable stainless steel cleaning cloth from customer service.
  • To prevent visible scratches, clean the stainless steel surface in the direction of the structure.

 



    See other models: TEPPAN1016 T18ID900RP PRG304WH PRD304WHU T24UW910RS

    Also, These documents are for others Thermador models: T24IF900SP, T30IF900SP, T36IF900SP

    Thermador T18IF900SP | File type: PDF | Filename: Thermador 18-Inch Built-in Panel Ready Freezer Column T18IF900SP.pdf | Size: 2.93 MB | Language: English, French, Spanish

    Download User Manual

    Product Infomation and Reviews - T18IF900SP photo

    T18IF900SP Photo

    T: @manualsFile

    https://manualsFile.com

    Thermador T18IF900SP Questions and Answers


    Thermador

    Thermador

    Owner manual PDF of Thermador T18IF900SP 18-Inch Built-in Panel Ready Freezer Column .

    Use manuals file type: PDF. Thermador - Refrigeration