Jenn-Air W10768190

User Manual - Page 21

For W10768190.

PDF File Manual, 48 pages, Download pdf file

Loading ...
Loading ...
Loading ...
21
Refer to the following chart for correct LP gas orice spud
ratings and to spud holder card for proper placement.
LP Gas Orifice Spud Chart for Surface Burners
Burner
Rating/Type Color Size (mm)
ID
Number Placement
15,000 BTU/
Stacked*
Silver
Black/
Orange
1.05
0.32
L105
L32
LF
14,200
BTU/ Ultra/
Stacked*
Silver 1.05 L105 LF/RF
8,000 BTU/
Semi
Red/
Orange
0.85 L85 RR/CTR
5,000 BTU/
Auxi
Red/
Blue
0.65 L65 LR
1,200 BTU/
Stacked/
Simmer*
Black/
Orange
0.32 L32 LF (Simmer)
*Not in all kits/models.
NOTE: Refer to the model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door
for proper sizing of spuds for each burner location.
6. Place Natural gas orice spuds in the orice spud bag.
IMPORTANT: Keep the Natural gas orice spuds in case
of reinstallation with Natural gas.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 1 to 7 for the remaining burners.
Complete Installation (Natural Gas to LP Gas)
1. Refer to the “Make Gas Connection” section for proper
connection of the range to the gas supply.
2. Refer to the “Electronic Ignition System” section for proper
burner ignition and operation.
3. Refer to the “Adjust Flame Height” section for burner ame
adjustments.
IMPORTANT: You may have to adjust the low setting for
each cooktop burner.
Checking for proper cooktop burner ame is very important.
Natural gas ames do not have yellow tips.
4. Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
IMPORTANT: Make sure to save the orifices that have
just been replaced in the conversion.
Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shut-off valve to the closed position.
A
B
C
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
(LP Gas to Natural Gas)
1. Move the range out from the wall.
2. Locate the gas pressure regulator at the lower right corner
on the back of the range.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
3. Remove the front lower panel of the range.
4. Disconnect the blower motor electrical connections.
5. Disconnect the downdraft blower bellows from the range.