Initial Lighting and Gas Flame Adjustments
Standard Surface Burners
Push in and turn each control knob to the ignite position.
The ame should light within 4 seconds. The rst time a burner
is lit, it may take longer than 4 seconds to light because of air
in the gas line.
If Burners Do Not Light Properly:
Turn cooktop control knob to the off position.
Check that the range is plugged into a grounded 3-prong
outlet. Check that the circuit breaker has not tripped
or the household fuse has not blown.
Check that the gas shut-off valves are set to the open
position.
Check that burner caps are properly positioned on
burner bases.
Repeat start-up. If a burner does not light at this point, turn
the control knobs to the off position and contact your dealer
or authorized service company for assistance. Please reference
the “Warranty” section of the Use and Care Guide to contact
service.
If the cooktop “low” burner ame needs to be adjusted for any
of the burners, see the “Adjust Flame Height” section.
If You Need Assistance or Service:
Please reference the “Warranty” section of the Use and Care
Guide to contact service.
Electronic Ignition System
Cooktop burners use electronic igniters in place of standing
pilots. When the cooktop control knob is turned to the ignite
position, the system creates a spark to light the burner.
All cooktop burners will spark, but only the burner with the
control knob turned to the ignite position will produce a ame.
This sparking continues as long as the control knob is turned
to the ignite position.
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas
to Natural gas must be done by a qualied installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shut-off valve to the closed position.
A
B
C
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.