Installation
*INSTALLATION*
65
Custom
door
panel
thickness
A
Gap X
for different
edge radii B
R0 R1.2 R2 R3
5/8"
-3/4"
(16-19
mm)
min. 1/8" (3 mm)
3/4"
(20 mm)
3/16"
(5
mm)
3/16"
(4
mm)
3/16"
(4
mm)
1/8"
(3.5
mm)
3/4"
(20 mm)
3/16"
(5.5
mm)
3/16"
(5
mm)
3/16"
(4.5
mm)
3/16"
(4
mm)
7/8"
(22 mm)
1/4"
(6.5
mm)
1/4"
(6
mm)
3/16"
(5.5
mm)
3/16"
(5
mm)
1 5/8"
(42 mm)
1/16"
(2 mm)
Adjoining housing unit door
A=Door panel thickness
B=Edge radius
X=Gap
1 5/8"
(42 mm)
1/16"
(2 mm)
Adjoining side wall
A=Door panel thickness
B=Edge radius
X=Gap
Tip: Fit a spacer between the housing
unit body and the side wall. This way
you will get a sufficiently wide gap.
Weight of the custom door panel
Before installing the custom door panel,
ensure that the weight of the door does
not exceed the maximum permitted
weight.
Wine condition-
ing unit
Maximum weight of
custom door pan-
elin
KWT6x22i(S) 44 lb (20 kg)
Fitting a custom door panel which is
heavier than the maximum permitted
weight could damage the hinges.