Value Series Manual 7
[1] A vent shall not terminate directly above a sidewalk or paved driveway
that is located between two single family dwellings and serves both
dwellings.
[2] Permied only if veranda, porch, deck, or balcony is fully open on a
minimum of two sides beneath the oor.
For clearances not specied in ANSI Z223.1/NFPA 54, clearances are in
accordance with local installaon codes and the requirements of the gas
supplier.
Clearance to opposite wall is 24 inches (60 cm).
For indoor models, you must install a vent terminaon to bring in combuson air and expel exhaust.
Direct Vent (Indoor Unit) Other than direct vent (Outdoor unit)
Ref Descripon
Canadian Installaons (CSA
B149.1)
US Installaons
(ANSI Z223.1 / NFPA 54)
Canadian Installaons
(CSA B149.1)
US Installaons
(ANSI Z223.1 / NFPA 54)
A
Clearance above grade, veranda, porch, deck, or
balcony
12 inches (30 cm) 12 inches (30 cm) 12 inches (30 cm) 12 inches (30 cm)
B Clearance to window or door that may be opened 36 inches (91 cm) 12 inches (30 cm)
6 in (15 cm) for appliances
10,000 Btuh (3 kW), 12 in (30
cm) for appliances > 10,000 Btuh
(3 kW) and ≤ 100,000 Btuh (30
kW), 36 in (91 cm) for appliances
>100,000 Btuh (30 kW)
4  (1.2 m) below or to side
of opening; 1  (300 mm)
above opening
C Clearance to permanently closed window * * * *
D
Vercal clearance to venlated sot, located
above the terminal within a horizontal distance of
2 feet (61 cm) from the center line of the terminal
* * * *
E Clearance to unvenlated sot * * * *
F Clearance to outside corner * * * *
G Clearance to inside corner * * * *
H
Clearance to each side of center line extended
above meter/regulator assembly
* * * *
I Clearance to service regulator vent outlet
Above a regulator within 3 
(91cm) horizontally of the
vercal center line of the
regulator vent outlet to a
maximum vercal distance of 15
 (4.5 m)
*
Above a regulator within 3 
(91cm) horizontally of the
vercal center line of the
regulator vent outlet to a
maximum vercal distance of 15
 (4.5 m)
*
J
Clearance to nonmechanical air supply inlet to
building or the combuson air inlet to any other
appliance
36 inches (91 cm) 12 inches (30 cm)
6 in (15 cm) for appliances
10,000 Btuh (3 kW), 12 in (30
cm) for appliances > 10,000 Btuh
(3 kW) and ≤ 100,000 Btuh (30
kW), 36 in (91 cm) for appliances
>100,000 Btuh (30 kW)
4  (1.2 m) below or to side
of opening; 1  (300 mm)
above opening
K Clearance to a mechanical air supply inlet 6 feet (1.83 m)
3 feet (91 cm) above if
within 10 feet (3 m)
horizontally
6 feet (1.83 m)
3 feet (91 cm) above if
within 10 feet (3 m)
horizontally
L
Clearance above paved sidewalk or paved
driveway located on public property
7 feet (2.13 m) * 7 feet (2.13 m) *
M Clearance under veranda, porch, deck, or balcony 12 inches (30 cm) * 12 inches (30 cm) *
Terminal Clearances
AIR SUPPLY INLET
VENT TERMINAL
AREA WHERE TERMINAL IS NOT PERMITTTED
X
V
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line