14 Value Series Manual
Flue Installaon (indoor models only)
Vercal Terminaon
(condensate collector must be used in all installaons)
3 in (75 mm)
minimum
3 in (75 mm)
minimum
Horizontal Terminaon using the
Condensate Collector
3 in (75 mm)
minimum
Condensate
Trap
To adjust the condensate collector posion or to
replace the female vent top with a male vent top:
1. Loosen the 4 screws at the rear bracket
2. Slide the bracket away from the female vent top.
3. Remove the 4 screws aaching the female vent top
to the water heater.
4. Li up the female vent top and reposion as desired
(or replace with a male vent top).
5. Install the 4 screws at the vent top and ghten the 4
screws at the bracket.
Secure the rst vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.
Bracket
Condensate Collector
Securing Screw
Horizontal Terminaon without using the Condensate Collector
Maximum Height *
5 feet (1.52 m)
Regions of cold climate will create more
condensate in the vent system. The
condensate collector should be used in
cold climates.
If more than one elbow is used in the
vercal secon the condensate collector
must be used.
* The condensate collector must be used in
horizontal terminaons if a vercal rise in
the vent system exceeds 5.
If the condensate collector is not used, the drain pipe
must be capped to prevent exhaust gases and
condensate from entering the building. The cap is
supplied on the appliance.
WARNING
Install the venng terminaon according to the diagrams and instrucons below.