20 Value Series Manual
Connect Electricity
Do not rely on the gas or water piping to ground the
water heater. A screw is provided in the juncon box
for the grounding connecon.
The water heater requires 120 VAC, 60 Hz power from
a properly grounded circuit.
If using the 5 foot long power cord, plug it into a
standard 3 prong 120 VAC, 60 Hz properly grounded
wall outlet.
On outdoor models, a disconnect switch must be
provided and installed for the incoming 120 VAC
power. It should be a type that is suitable for outdoor
use. Check the Naonal Electrical Code, ANSI/NFPA
70 and your local codes for a proper switch type to
use in your area.
The wiring diagram is located on the Technical Sheet
aached to the inside of the front cover.
WARNING
Do not use an extension cord or an adapter plug with
this appliance.
The water heater must be electrically grounded in
accordance with local codes and ordinances or, in the
absence of local codes, in accordance with the
Naonal Electrical Code, ANSI/NFPA 70.
Indoor water heaters are equipped with a three-
prong (grounding) plug for your protecon against
shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding terminal from this plug.
Checklist for Gas and Electricity
A manual gas control valve is placed in the gas
line to the water heater.
Check the gas lines and connecons for leaks.
Conrm that the gas inlet pressure is within
limits.
Conrm that the water heater is rated for the gas
type supplied.
Conrm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
An extension cord or an adapter plug has not
been used with the water heater.
Adjust for High Altude
In DIPSW 1, set SW 2 and SW 3 to the values shown in
table below for your altude. The default seng for
the appliance is 0-2000  (0-610 m) with SW 2 and
SW 3 in the OFF posion. When the DIP switch is
adjusted, it is not necessary to adjust the gas pressure
seng for high altude.
Altude
SW 2 in
DIPSW 1
SW 3 in
DIPSW 1
0-2000  (0-610 m) OFF OFF
2001-5200  (610-1585 m) OFF ON
5201-7700  (1585-2347 m) ON OFF
7701-10200  (2347-3109 m) ON ON
Adjust for Vent Length
(indoor models only)
Adjust SW 1 in DIPSW 1 if required. Refer to the
secon “Maximum vent length”.
REMOTE CONTROL
CONNECTION
TERMINALS
REMOTE CONTROL CABLE
CABLE CLAMP
CABLE
CLAMP
SWITCH
120V Wiring
Blue or Black Wire: Hot Leg
Brown or White Wire: Neutral
GROUND
CONNECTION
SCREW
DIPSW 1
DIPSW 2