18 Value Series Manual
Connect Water Heater to Water Supply
Water connecons to the tankless water heater
should follow all state and local plumbing codes.
If this is a standard installaon, refer to the Piping
Diagram for Basic Installaon.
1. Plumb water supply to the tankless water heater
on the 3/4” MNPT connecon at the boom of
the unit marked “Water Inlet”, which is the cold
water supply.
2. Plumb the building hot water supply to the 3/4”
MNPT connecon marked “Water Outlet”, which
is the hot water supply.
If a pipe cover will be installed, make sure water lines
to the water heater t.
Checklist for Plumbing
Purge the water line of all debris and air by
closing the hot isolaon valve and opening the
cold isolaon valve and its drain. Debris will
damage the water heater. Use a bucket or hose
if necessary.
Ensure that hot and cold water lines are not
crossed to the unit and are leak free.
Ensure that a pressure relief valve is installed with
a rang that exceeds the BTU input of the water
heater model. Refer to the rang plate on the
side of the water heater for BTU input.
Clean the inlet water lter by closing the cold and
hot water inlet isolaon (shut-o) valves. Put a
bucket under the lter at the boom of the water
heater to catch any water that is contained inside
the unit. Unscrew the water lter. Rinse the
lter to remove any debris. Install the lter and
open the isolaon valves.
Check for proper water pressure to the water
heater. Minimum water pressure is 20 psi. Rinnai
recommends 30-80 psi for opmal performance.
Installaon of Gas Supply
MUST DO
A manual gas control valve must be placed in the
gas supply line to the water heater. A union can be
used on the connecon above the shut o valve
for the future servicing or disconnecon of the
unit.
Check the type of gas and the gas inlet pressure
before connecng the water heater. If the water
heater is not of the gas type that the building is
supplied with, DO NOT connect the water heater.
Contact the dealer for the proper unit to match the
gas type.
Check the gas supply pressure immediately
upstream at a locaon provided by the gas
company. Supplied gas pressure must be within
the limits shown in the Specicaons secon with
all gas appliances operang.
Before placing the appliance in operaon all joints
including the heater must be checked for gas
ghtness by means of leak detector soluon, soap
and water, or an equivalent nonammable
soluon, as applicable. (Since some leak test
soluons, including soap and water, may cause
corrosion or stress cracking, the piping shall be
rinsed with water aer tesng, unless it has been
determined that the leak test soluon is non-
corrosive.)
Use approved connectors to connect the unit to
the gas line. Purge the gas line of any debris
before connecon to the water heater.
General Instrucons
WARNING
1. A licensed professional must install the gas
supply.
2. Turn o 120v power supply.
3. Turn o the gas.
4. Gas is ammable. Do not smoke or provide other
ignion sources while working with gas.
5. Do not turn on the water heater or gas unl all
fumes are gone.