23
www.insigniaproducts.com
NS-FDRE44W1/NS-FDRE44W1-C
INSTALLATION INSTRUCTIONS
4 Connect the other wires to the outer terminal block screws. Make sure that
you cross the screws through the terminal rings, then tighten the screws.
5 Tighten the strain relief screws.
6 Insert the tab on the terminal block cover into your dryer's rear panel slot,
then secure the cover with a screw.
WARNING:
We recommend using ring-type terminals. If you use strap terminals, make
sure that they are tightened.
WARNING:
Risk Of Electric Shock - All U.S. models are produced for a 3-WIRE SYSTEM
CONNECTION.
The dryer frame is grounded to the neutral conductor at the terminal block.
A 4-WIRE SYSTEM CONNECTION is required for new or remodeled
construction, mobile homes, or if local codes do not permit grounding
through neutral conductor.
If the 4-wire system is used, the dryer frame cannot be grounded to the
neutral conductor at the terminal block. See to the “Electric requirements
on page 18 for 3-wire or 4-wire system connections.
Remove the terminal block cover plate. Insert the power cord with a
UL-listed strain relief through the hose provided in the cabinet near the
terminal block. A strain relief must be used. Do not loosen the nuts already
installed on the terminal block. Be sure they are tight. Use a 3/8 in. (1 cm)
deep well socket.