Console programs do not start
• Perform Keypad test in Maintenance mode
• If you cannot access the test, and the keys seem to have no aect
when pressed, then the keypad has malfunctioned.
Program starts but no data registers when bike is pedaled
• Check that the connectors are properly seated in the back of the
consoles.
• Perform the Sensor tests in Maintenance mode. If one of the sen-
sors does not work it needs replacement. If both sensors do not
work then it could be a bad console or both sensors are bad.
Symmetry measurement is incorrect
• Perform the sensor tests in Maintenance Mode
• If sensors are functioning then perform Crank Position Calibration
• If calibration is ok then check the Unit Type is set to 7.0 R.
Pedal resistance seems harder/dierent than before
Check the watts per level setting in the Set Up menu (see page 9).
The default setting from the factory is 5 watts per level..
Cannot adjust seat fore/aft or back angle, or seat adjust-
ments will not lock in place
Adjust the thumb nuts located to the rear of the seat adjustment
levers. If the cables attached to the levers stretch it is possible the
latch for the seat will not disengage, or engage, properly. Adjusting
the thumb nut can remedy this.