Karcher 11035100 Compact CoAg Water Management Center

User Manual - Page 15

For 11035100.

PDF File Manual, 34 pages, Read Online | Download pdf file

11035100 photo
Loading ...
Loading ...
Loading ...
Water Maze Compact CoAg • 9.801-506.0-D
15
WATER TREATMENT SYSTEM
DEALER MANUAL
(Variable Speed Peristaltic)
TECHNICAL INFORMATION
Materials:
Squeeze Tubing Special synthetic rub ber
Strainer and
Injection Point Fitting PVC
Feed Rate: 1-7 or 8-45 GPD
Tubing Size: 1-7 or 8-45 GPD
Dimensions: Height = 5"
Width = 4"
Depth = 4 1/4"
Standard Accessories Provided with Pump:
Squeeze Tubing
Check Valve Assembly
Strainer with weight
Bulkhead fi tting with elbow
Electrical Rating:
20-265 VAC
7 W
50/60 Hz
Maximum System Pressure: 45 PSI
INSTALLATION
1. SUCTION TUBING: Take the 5 ft. length of 1/4"
O.D. tubing in clud ed, measure and cut the lengths
needed to run from pump head to the chemical
tank. Cut the tubing ends square.
Indicator Light
Cover
Screws
Pump Rollers
2. CONNECT SUCTION TUBING TO PUMP: Re-
move compression fi tting. Feed tube through fi t-
ting. Push end of the tube on fi tting. Tighten fi tting
rmly.
NOTE: To soften the end of the tubing, im merse it
in hot water.
3. CONNECT SUCTION TUBING TO STRAINER:
In stall strainer so it’s off the bottom of the chemi-
cal con tain er. Cut the suction tub ing to the length
need ed. Put weight on tubing. Push strainer end
into tubing.
METERING PUMP
OPERATION
If not already done, put the end of the suction tub ing
into the chemical container, near the bottom.
Move the “ON-OFF” switch to ON.
PRIME: To prime the pump and lines push the 3-way
switch to full speed.
FEED ADJUSTMENT: (ONLY A QUALIFIED WATER
MAZE SERVICE TECH NI CIAN SHOULD MAKE THIS
AD JUST MENT.) The feed adjustment is under the
cover plate. Remove the plate and turn the adjusting
screws clockwise to in crease feed or counterclockwise
to decrease feed.
METERING PUMPS
Chemical
Container
Suction
Tube
Discharge
Tube
Check Valve
Speed
Adjustment
Power
Cord
Strainer
Inlet
Squeeze
Tube
Speed
Adjusting
screw with
Indexing
Mark
On-Off-Full
Speed Switch
(right or left
side)
Discharge
1 2
Strainer
End
Weight
Suction
Tube
Loading ...
Loading ...
Loading ...