Typical Application Diagrams for Proper Connections
Sample setups to indicate the basic
configuration for proper connections.
Protecting all AC and signal lines will
keep your system safe and ensure
compliance with Panamax’s Connected
Equipment Policy.
COAX
TEL
AC OUTLET
MOD-
DBS TV
ROUTER
WIFI
SM3-PRO FRONT
SM3-PRO BACK
VOIP MODEM
E
L
TEL
COAX
AC
AC
AC
LAN
14 AWG WIRE
LAN
DISPLAY
COAX
LAN
TEL
AC
OUTLET
MOD-
DBSTV
MEDIA PLAYER
SM3-PRO FRONT
SM3-PRO BACK
SAT
E
L
TEL
COAX
AC
14 AWG WIRE
LAN
HDMI
AC
LAN
AC
HDMI
LAN
Diagram 1
Diagram 2
Rear Panel Features Overview
3
BANK 1
ETHERNET 1
SM3-PRO SYSTEM MANAGER
ETHERNET 2
BANK 2
UNSAFE
VOLTAGE
WIRING
FAULT
BlueBOLT ACC 1 ACC 2
RESET
OUTLET
1
120V / 60Hz
GROUND
BANK 1
BANK 2
OUTLET
2
OUTLET
3
15A
Outlets: The three rear panel outlets are grouped into two switched outlet banks.
(Outlets within an outlet bank are controlled together).
1. Bank 1 has one outlet.
2. Bank 2 has two outlets.
1
2
3 54
3. Resettable 15A Circuit Breaker
4. Power Inlet: 120 Vac / 15A, IEC 320-C13 with plug/cord retention clip.
5. Ground Lug: connect to Panamax MOD-series signal protection module
grounding busses with 14AWG (<12” length) wire to expand the signal
protection capabilities.