Panamax SM3-PRO Compact BlueBOLT System Manager SM3PRO

User Manual - Page 13

For SM3-PRO.

PDF File Manual, 16 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
11
Element Tag: <outlet>
Attribute: id = “bank” “bank” is the affected outlet bank number
Content 0 | 1 0 = outlet bank is OFF
1 = outlet bank is ON
Example: <outlet id=”1”>0</outlet> Outlet bank 1 is OFF
EVENTS
Event messages are sent autonomously from SM3-PRO when some change occurs within the device – they are not replies to a query.
Subscribing to Event Messages
After start-up, SM3-PRO will not send any event messages. To receive event messages a command to “subscribe” to events must be sent.
The event subscription command is enclosed within the XML declaration and <device> element and is as follows:
...<commands><eventmgr><subscribe uri=”ctrlsys://IPADDR:PORT”/></eventmgr></commands>...
IPADDR is the IP address and port number where the event messages should be sent. It may be a different IP address than the control system which sent the request.
PORT is the UDP port number.
Only one IP address / port event subscription is allowed.
For example, to have event messages sent from a SM3-PRO with MAC address 10-65-A3-03-FF-FF to a control system at IP address 192.168.0.127 listening
on port 1726:
<?xml version=”1.0” ?><device class=”sm3” id=”1065a304ffff”><command><eventmgr><subscribe
uri=”ctrlsys://192.168.0.127:1726”/></eventmgr></command></device>
The unsubscribe command follows the same format
...<commands><eventmgr><unsubscribe uri=”ctrlsys://IPADDR:PORT”/></eventmgr></commands>...
General Event Element Structure
All event messages are contained within an <event> element, which will contain a timestamp attribute, “time”, and an event ID attribute, “evtid”. The time attribute is
a UNIX timestamp, up to 10 decimal digit characters and represents the number of seconds that have passed since January 1st 1970 GMT. The evtid attribute is the
numeric ID value of the event message, starting from 0 after each device start-up.
Event Messages:
Outlet State Change
An Outlet State Change event is posted when any of the outlet banks turn ON->OFF or OFF->ON.
Element Tag: <seq>
Attribute: None
Content 0 | 1 | 2 0 = sequence done/finished/complete
1 = turn on sequence initiated
2 = turn off sequence initiated
Example: <seq>0</seq> Sequence has completed
Sequence Status
A Sequence Status event is posted when a power on or power off sequence is initiated or completed.
A subscriber ID, “subsid” is assigned to each event subscription and is included in every event message sent to the subscriber.
A sample event message for outlet bank 2 switching ON:
…<event time=”1234567890” evtid=”123” subsid=”1”><outlet id=”2”>1</outlet></event></device>
Event messages will be repeated until an acknowledgement message is sent back to SM3-PRO, or after a timeout period of approximately 20 minutes. The acknowl-
edgement message syntax is:
…<command><eventmgr><ack evtid=”123” subsid=”1”></eventmgr></command></device>
Loading ...
Loading ...