SAFETY PRECAUTIONS - BEFORE YOU BEGIN
(CONTINUED)
GAS
SUPPLY
TO
APPLIANCE
SHUTOFF VALVE
IN OPEN POSITION
ELECTRICAL SUPPLYELECTRICAL SUPPLY
This appliance must be connected to a dedicated circuit, 120 VAC, Single Phase, 60 Hz, with
a current rating as shown in ”MODEL NUMBERS” on page 8 Have the installer show you
where the electric circuit breaker is located so you know how to shut off the power to this
appliance. It is the responsibility of the user to have the appliance connected by a licensed
electrician in accordance with all local codes, or in the absence of local codes, in accordance
with the National Electrical Code. Read the ELECTRICAL CONNECTIONS section of the
Installation Manual for complete details.
GAS SUPPLYGAS SUPPLY
A gas shut-off valve must be located in an easily
accessible location for servicing of the cooktop. Make
sure all users of the cooktop know where this shut-off is
located, and how to shut off the gas.
The type of gas should be verified prior to installation
and operation of this appliance. It is the responsibility of
the user to have the appliance connected by a licensed
plumber in accordance with all local codes, or in the
absence of local codes, in accordance with the National
Fuel Gas Code.
When connecting to LP gas, verify the tank is equipped
with its own high pressure regulator. The pressure of the
gas supplied to the appliance must not exceed 11.0” WC
[2.74 kPa]. Consult the Installation Manual for details
on gas type, gas pressure, connection and leak testing
instructions, etc.
Read the GAS CONNECTIONS section of the Installation Manual for complete details.
CONVERSION KITSCONVERSION KITS
In the event your Hestan appliance needs to be converted from NG to LP, or vice-versa, you
will need to contact Hestan Customer Service to arrange a service call. This conversion can
only be performed by a qualified technician.
VENTILATION REQUIREMENTSVENTILATION REQUIREMENTS
It is strongly recommended that this appliance be installed with a Hestan vent hood. Hestan
vent hoods have been matched up to the BTU output of the cooktop. Due to the high heat
output of this cooktop, it is very important that the hood and ductwork installation meets
local building codes and is installed by a qualified technician.
Do not use a down-draft style ventilation system.
Do not mount a microwave oven/ventilator combination above the cooktop. This type of unit
does not have sufficient airflow to remove the high heat output of this cooktop.
Consult the Installation Manual for further details.
Consult with your Hestan dealer on selecting the appropriate vent hood for your
Hestan appliance.