You can connect the RS-485 terminal with the RS-485 card reader,
connect the NC and COM terminal with the door lock, connect
the SENSOR terminal with the door contact, the BTN/GND
terminal with the exit buon, connect the alarm output and input
terminal with the alarm output/input devices, and connect the
Wiegand terminal with the Wiegand card reader or the access
controller.
If connect the WIEGAND terminal with the access controller, the
face recognion terminal can transmit the authencaon
informaon to the access controller and the access controller can
judge whether to open the door or not.
Note
If cable size is 18 AWG, you should use a 12 V power supply.
And the distance between the power supply and the device
should be no more than 20 m.
If the cable size is 15 AWG, you should use a 12 V power
supply. And the distance between the power supply and the
device should be no more than 30 m.
If the cable size is 12 AWG, you should use a 12 V power
supply. And the distance between the power supply and the
device should be no more than 40 m.
4.1 Terminal Descripon
The terminals contains power input, alarm input, alarm output,
RS-485, Wiegand output, and door lock.
The terminal's diagram is as follows:
Figure 4-1 Terminal Diagram
The descripons of the terminals are as follows: