AX PRO User Manual
21
will be triggered.
Wi-Fi Fault Check
If the option is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be
triggered.
Cellular Network Fault Check
If the option is enabled, when the cellular data network is disconnected or with other faults, the
alarm will be triggered.
AC Power Down Check Time
The system checks the fault after the configured time duration after AC power down.
To compliant the EN 50131-3, the check time duration should be 10 s.
System Instructions
In the site, tap the AX PRO and then log in to the device (if required). Tap → System →
System Options → System Instructions to enter the page.
Stop Arming
If the option is enabled, when there is a fault during the arming procedure., you can stop arming
manually.
Fault Check
The system will check if the device has the faults in the checklist during the arming procedure.
Arming with Fault
Check the faults in the Fault Check list, and the device will not stop the arming procedure when
faults occurred.
Arming Indicator Keeps Light
If the device applies EN standard, by default, the function is disabled. In this case, if the device is
armed, the indicator will be solid blue for 5 s. And if the device is disarmed, the indicator will
flash 5 times.
When the function is enabled, if the device is armed, the indicator will be on all the time. And if
the device is disarmed, the indicator will be off.
Prompt Fault When Arming
If the device applies EN standard, by default, the function is disabled. In this case, the device will
not prompt faults during the arming procedure.
Early Alarm
If you enable the function, when the zone is armed and the zone is triggered, the alarm will be
triggered after the delay time.
Delay Time
When the early alarm function is enabled, you should set the delay time. The alarm will be
triggered after the configured delay time.