Hikvision HM-TD5567T-15/W Bi-spectrum Thermography Mini Positioning system

User Manual - Page 60

For HM-TD5567T-15/W.

PDF File Manual, 138 pages, Read Online | Download pdf file

HM-TD5567T-15/W photo
Loading ...
Loading ...
Loading ...
Steps
1.
Go to Conî´ªguration > Event > Basic Event > Alarm Input .
2.
Check Enable Alarm Input Handling.
3.
Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4.
Refer to
Set Arming Schedule
for setting scheduled time. Refer to
Linkage Method
Settings
for setting linkage method.
5.
Click Copy to... to copy the settings to other alarm input channels.
6.
Click Save.
8.4 Set Exception Alarm
Exception such as network disconnection can trigger the device to take corresponding
action.
Steps
1.
Go to Conî´ªguration > Event > Basic Event > Exception .
2.
Select Exception Type.
HDD Full The HDD storage is full.
HDD Error Error occurs in HDD.
Network Disconnected The device is ofî´«ine.
IP Address Conî´«icted The IP address of current device is same as that of other
device in the network.
Illegal Login Incorrect user name or password is entered.
Voltage Instable The power supply voltage is î´«uctuating.
PT Locking The panning and tilting movements are stuck.
3.
Refer to
Linkage Method Settings
for setting linkage method.
4.
Click Save.
8.5 Set Burning-Prevention
This function is used to close the shutter to prevent the lens from high temperature
damage.
Steps
1.
Go to Conî´ªguration > Event > Basic Event > Burning-Prevention .
2.
Check Enable.
3.
Select burning-prevention mode.
Lens Movement
The lens move automatically to avoid high temperature damage.
Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
43
Loading ...
Loading ...
Loading ...