Chapter 3 Temperature Measurement
When you enable this function, the device measures the actual temperature of the scene. It
alarms when temperature exceeds the temperature threshold value.
Note
The function varies according to different camera models.
3.1 Notice
This part introduces the notices of conguring temperature measurement function.
The target surface should be as vertical to the optical axis as possible. It is
recommended that the angle of oblique image plane should be less than 45°.
The target image pixels should be more than 5 × 5.
If multiple presets will be taken for temperature measurement, it is recommended to set
the patrol time above 20 s.
Please select line thermography or area thermography for a certain area temperature
measurement. The point thermography is not recommended in case of deviation
occurred during device movement to affect the accuracy of temperature measurement.
3.2 Thermography Conguration Flow Chart
This part introduces the process of conguring temperature measurement.
Thermal & Optical Bi-spectrum PTZ Network Camera User Manual