PL5 Series Fiber Laser Marking System Page 30 of 40
5.3.4 Lens Correction
Select the Settings on the home screen, enter to Settings. Select “Lens”, enter 100 in the
blank of “ Working Scope” (100mm is the size of galvameter scanner), then click “Enable”.
Correct Method #1: Correction Table
Process:
1. First enter the "Working Scope" and go back to the home screen to refresh, and then go
back to the interface shown above.
2. Do not click the "XY Swap", "X", "Y" radio button before correction.
3. Click the "enable" button then click laser test, the machine will print a ‘田’ shape.