Rohde & Schwarz NGP824 power supply

NGP800 series manual - Page 123

For NGP824.

PDF File Manual, 190 pages, Read Online | Download pdf file

NGP824 photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
NGP800
121User Manual 5601.5610.02 ─ 04
CURR UP
// queries the current step size
CURR:STEP?
// response: 1.0000
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]....................................................... 121
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]............................................. 122
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <New value for current>[,
<Channel list>]
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [<Channel list>]
Sets or queries the current value of the selected channel.
Parameters:
<current> <numeric value> | MIN | MINimum | MAX | MAXimum | UP |
DOWN | <list>
<numeric value>
Numeric value in the range of 0.000 to 20.0100 .
MIN | MINimum
Minimum current at 0.0005 A.
MAX | MAXimum
Depending on the set voltage level, the maximum set current is
20.0100 A.
For voltage range up to 32 V, maximum set current is 20.0100 A.
For voltage range up to 64 V, maximum set current is 10.0100 A.
UP
Increases current by a defined step size. See
[SOURce:
]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
on page 122.
DOWN
Decreases current by a defined step size. See
[SOURce:
]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
on page 122.
Parameters for setting and query:
<Channel list> <list>
Example:
CURR? (@1)
Queries the current at channel 1.
Example: See
Example "Configuring the current output" on page 120.
Configuration Commands
Loading ...
Loading ...
Loading ...