223
19.4.14 Condenser Fan:
The condenser fan is used to force air over the condenser coil. The condenser fan cycles on and
off simultaneously at intervals during the production and harvest cycles.
1. Make sure that the motor shaft turns freely. The blade can be turned in either direction
to verify that the shaft is not ceased or the blade binding. Watch the blade and listen for
any noise that might indicate a problem.
2. Check resistance between the terminals of the motors power cord. Replace the motor if
the windings are shorted (open).
19.4.14.1 Fan Assembly Removal
1. First, remove the fan blade from the motor shaft.
2. Remove the two Phillips screws securing the fan motor to the mounting bracket.
3. The fan assembly can now be lifted clear from the fan bracket and shroud.
4. Disconnect the fan assembly at the connector harness.
19.4.14.2 Exploded View of Condenser Fan assembly
Loading ...
Loading ...
Loading ...