125
15.7: Compartment Fan Operation
Upper compartment; blows air out into the compartment, circulates supply air into the
compartment. The blade rotates in a clockwise rotation as you face the hub.
Lower compartment; draws air out of the compartment, return air is brought back into
the evaporator compartment to be reconditioned. The blade rotates in a counter-
clockwise rotation as you face the hub.
Top Compartment
Bottom Compartment
Clockwise Rotation
Counter-Clockwise Rotation