Hisense WFGC801439VM 3+ Series 8kg Washing Machine

USER ́S OPERATION MANUAL - Page 42

For WFGC801439VM. Series: 3+ Series

PDF File Manual, 52 pages, Read Online | Download pdf file

WFGC801439VM photo
Loading ...
Loading ...
Loading ...
864036
42
Problem/
error
Indication on the display unit
and problem description
What to do?
Error while unlocking the door. Door is closed, but it cannot be unlocked.
Turn off the washing machine, then turn it
back on. If the error reoccurs, call a service
technician. To open the door, see chapter
»INTERRUPTIONS AND CHANGING THE
PROGRAMME/Opening the door manually«.
Electronics communication
failure in the washing machine
Unplug the power cord from the outlet; then,
plug the power cord back into the outlet and
switch on the washing machine.
If the error reoccurs, call a service technician.
Electronics communication
failure in the washing machine
Unplug the power cord from the outlet; then,
plug the power cord back into the outlet and
switch on the washing machine.
If the error reoccurs, call a service technician.
Warning from the system for
detecting extended washing
machine voltage fluctuation –
180 V > U > 260 V
A prolonged drop of voltage do below 180 V,
or voltage in excess of 260 V was detected,
which can affect the washing machine
operation.
Check the power supply network to which your
washing machine is connected.
Warning from the system for
detecting incorrect power
mains frequency (50/60 Hz)
When the washing machine was switched
on, the system detected incorrect supply
power frequency, which could affect washing
machine functionality.
Any problems on the power network should be
checked and corrected.
Warnings/information for the user, which can be indicated on the display unit, may include the
following:
Warning/
information
Indication on the display unit Error cause and description, what to do?
ANTICREASE function that
you have selected as a part
of the washing programme is
activated and in progress.
To stop the ANTICREASE function, press
the (1) ON/OFF button.
Water drain system alert
Display of warning
.
Alert about reduced water flow in the pumping
stage. Check the following:
is the pump filter clean,
is the discharge hose clogged,
is the drain clogged,
if the discharge hose placed is placed below
the maximum and above the minimum
height (see chapter »INSTALLATION AND
CONNECTION/Connecting and securing the
water discharge hose«).
Loading ...