Installation Manual - Page 33

For 3U24GS1ERE. Also, The document are for others Haier models: 2U18MS2VHB, 3U24MS2VHB, 4U36MS2VHB, AB09SC2VH*, AB12SC2VH*, AB18SC2VH*, AW07LC2VH*, AW09LC2VH*, AW12LC2VH*, AW18LC2VH*, AD07SL2VH*, AD09SL2VH*, AD12SL2VH*, AD18SL2VH*

Loading ...
Loading ...
Loading ...
REMOTE CONTROL FUNCTIONS
PAGE 33
ENGLISH
the time. After replacing batteries or a power failure occurs,
the time setting will need to be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
13
SLEEP Button
Sleep mode
Press the Extra Function
button to enter additional
options, cycle the button to display the
icon, the

button to
enter the sleep function.
Sleep Operation Mode
1. SLEEP mode during COOL, DRY modes
One hour after SLEEP mode starts, the temperature will
rise 2°F above set temperature, after another hour, the
temperature rises an additional 2°F. The unit will run for an

is 4°F higher than the initial set temperature. Using this

comfort from your unit while you sleep.
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 2
O
F
Rises 2
O
F
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
2. SLEEP mode during HEAT mode
One hour after SLEEP mode starts, the temperature will
decrease 4°F below set temperature, after another hour,
the temperature will decrease an additional 4°F. After an
additional three hours, the temperature will rise by 2°F.
The unit will run for an additional three hours, then turns

temperature. Using this feature will help with achieving

sleep.
SLEEP
operation starts
SLEEP
operation stops
1 hr
1 hr
3 hrs
3 hrs
Rises 3
O
F
Temp.setting
Unit stop
In HEAT mode
Decreases 4
O
F
Decreases 4
O
F
3. In AUTO mode
The unit operates in corresponding sleep mode adapted
to the automatically selected operation mode.
Note:
-When the unit is set to sleep mode, the fan speed will be
set to low speed and cannot be changed.
-When the TIMER function is set, the sleeping function
cannot be set. If the sleeping function has been set, and
the user sets the TIMER function, the sleeping function
will be canceled, and the unit will be set to the timer
function.
14
EXTRA FUNCTION Button
Function:
A) Refresh air - Feature not available on this series.
B) A-B Yard - This will allow you to control two separate units
with a single remote control.
Note: this feature would be setup at the time of installation
by the contractor.
C) Fan Mode - Is indicated by the
icon. Only the fan will
operate in this mode. See section 8 “FAN Button” for
changing the fan settings.
D) Intelligent upward airow, E) Intelligent downward airow,
F) Reset intelligent airow position
1. Press the ON/OFF button on the remote control to turn
the unit on.
Select the desired operating mode.

Press the EXTRA FUNCTION
button to enter ad-
ditional options. Press this button repeatedly to access
the louver settings. The louver icon will cycle through the
following three settings.
Healthy
airflow
upward
Healthy
airflow
downward
Present
position
Select the desired position, then press the CONFIRM/
CANCEL
button to set the function.

Press the EXTRA FUNCTION
button to enter addi-
tional options. Press this button repeatedly to access the
louver settings. Cycle the button to the louver icon “pres-
ent” position, then press the CONFIRM/CANCEL
button to cancel the function.
Notice: Do not reposition the horizontal louver by hand.
This may cause the louver to run incorrectly and not
match the icon displayed on the remote control. If the

minute, then back on, and adjust the louver setting with
the remote control.
Note:


2. In cooling, it is better to select the
mode.
3. In heating, it is better to select the
mode.
4. In cooling and dry modes, using the air conditioner for a
long period of time under high humidity conditions, con-
densate water may form on the grille/louver.
Loading ...
Loading ...
Loading ...