INSTALLATION
PAGE 20
ENGLISH
Wall Mount Product Information
Introduction - Overview
The Wall Mount Indoor Air Handler consists of a single
compact unit, operated via a factory supplied remote control.
A display indicator located on the front panel of the unit
provides temperature and operating modes of the system. It
can also display error code conditions of the system.
The wall mount unit receives 230 volt line voltage from a
terminal connection at the outdoor condensing unit. There is
no requirement for independent line voltage connections.
Piping to the unit may be routed from one of several
directions. (Left, left back, left down, right, right back and
right down.)
A motorized louver at the front of the unit is controlled via the
remote control. The louver may be set to either oscillate or
remain in a stationary position.
Manual vanes located behind the louver may be set to help



Factory Supplied
Remote
Display
Mounting Bracket
Indoor Unit Installation - Wall Mount
Wall Mount Indoor Unit Specications
Indoor AW07LC2VHA AW09LC2VHA AW12LC2VHA AW18LC2VHA
Rated Cooling Capacity Btu/hr 7,000 9,000 12,000 18,000
Rated Heating Capacity Btu/hr 8,000 10,000 13,000 19,000
Voltage, Cycle, Phase V/Hz/- 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Fan Speed Stages 5+Auto 5+Auto 5+Auto 5+Auto

Quiet) CFM
410/350/295/235/205 410/350/295/235/205 440/380/320/265/215 636/530/483/430/383
Motor Speed (Turbo/High/Med/
Low/Quiet) RPM
1050/950/800/650/600 1050/950/800/650/600 1100/1000/850/700/620 1100/950/850/750/600
Indoor Sound Level dB (Turbo/
High/Med/Low/Quiet)
43/38/33/26/22 43/38/33/26/22 44/39/34/27/23 48/45/40/35/30
Dimension: Height in (mm) 11 (280) 11 (280) 11 (280) 12 3/4 (332)
Dimension: Width in (mm) 33 5/8 (855) 33 5/8 (855) 33 5/8 (855) 39 1/4 (997)
Dimension: Depth in (mm) 8 1/16 (204) 8 1/16 (204) 8 1/16 (204) 9 1/4 (235)
Weight (Ship/Net)- lbs (kg) 26.8/22(12.2/10) 26.8/22(12.2/10) 26.8/22(12.2/10) 35.3/28.6 (16/13)
Connections Flare Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 1/2
Drainpipe Size O.D. in 5/8 5/8 5/8 5/8