Adjustment Section:
Adjustment Step 1
Adjust the UP and DOWN Limits
Do not make any limit adjustments unUIthe
safety reversing sensors are completely
Installed.
Umit adjustment settings regulate the points at
which the door will stopwhen moving up or down.
The door will stop in the up direction if anything
interferes with door travel. The door will reverse in
the down direction ifanything interferes with the
door travel (including binding or unbalanced doom).
To operate the opener, press the Wall Control push
bar. Run the opener through a complete travel
cycle.
Does the door open and close completely?
Does the door stay closed end not reverse
unintentionally when fully closed?
If your door passes both of these tests, no limit
adjustments are necessary unless the reversing test
falls (See page 30).
Pages 28 - 30
Urr_
_lu_mer4
Screws
............... -/o o _'_=
LeftSidePan_
Adjustment procedures are outlined below. Run
the opener through a complete travel cycle after
each adjustment.
Repeated operation of the opener during
adjustment procedures may cause the motor to
overheat and shut off. Simply walt 15 minutes
and try again.
Read the procedures carefully before proceeding to
Adjustment Step 2. Use a screwdriver to make limit
adjustments.
How and When to Adjust the Limits
If the door does not open completely
but opens at/eaat five feet
Increase up travel. Turn the UP limitadjustment
screw clockwise. One tum equals 2" of travel.
If door does not open at least 5 feet: Adjust the
UP (open) force as explained in Adjustment Step 2.
If the door does not close completely
increase down travel. Tum the DOWN limit
adjustment screw counterclockwise. One turn
equals 2" of travel.
If door still won1 close completely, try lengthening
the door arm. (Page 26.)
If you have adjusted the door arm to the maximum
length and the door still will not close completely,
lower the header bracket. See Installation Step 1,
pages 12/13.
If the opener reverses In fully closed pesitlon
Decrease downtravel. Turn the DOWN limit
adjustment screw clockwise. One tum equals 2" of
travel.
ff thq door reverses when closing and
there is no visible Interference to travel cycle
If the opener lights are flashing, the Safety Reversing
Sensor is obstructed. Remove the obstruction.
Test the door for binding: Pull the emergency release
handle. Manually open and close the door. If the door
is binding, call for garage door service. If the door is
not binding or unbalanced, adjust the DOWN (close)
force. See Adjustment Step 2.
28