162
5. CLI Commands
schedule: restart
restart
Use the restart command to set the restart delay time for the scheduled action entry. The restart delay sets the time that
must elapse (after shutdown completes) before the device turns on. The default value is zero (0), which will cause the
immediate restart of the device after shutdown. The unit of measure for delay times is typically seconds, but will vary by device
model. Not all device models support restart delay times. This command applies only to action type “restart-device”.
Syntax
restart <delay>
delay – Specifies the restart delay time, in seconds, for the “restart-device” scheduled action entry (Range: 0-65535).
Examples
The following command sets a restart delay of 60 seconds for scheduled action entry “WeeklyRestart”:
console> schedule (WeeklyRestart)> restart 60
Update complete
show restart
Use the show restart command to display the restart delay time for the scheduled action entry. This command applies only to
action type “restart-device”.
Syntax
show restart
Examples
The following command displays the restart delay time for scheduled action entry “WeeklyRestart”:
console> schedule (WeeklyRestart)> show restart
60