6. Menu Display and Settings
86
Paint Menu
This section describes the function and settings of each menu item.
Factory default settings are shown in bold (for example, 18dB).
Paint >Black
Sets black settings.
Item Sub-item setting Description
Master Black –99.0 to +99.0 (±0.0) Sets the master black level.
R Black
–99.0 to +99.0 (±0.0) Sets the R black level.
B Black
–99.0 to +99.0 (±0.0) Sets the B black level.
Paint >Gamma
Sets gamma correction settings.
Item Sub-item setting Description
Setting On / Off Turns the gamma correction function on/
off.
Step Gamma
0.35 to 0.45 to 0.90 Sets a gamma correction value in 0.05
steps.
Master
Gamma
–99 to +99 (±0) Sets the master gamma level.
R Gamma
–99 to +99 (±0) Sets the R gamma level.
G Gamma
–99 to +99 (±0) Sets the G gamma level.
B Gamma
–99 to +99 (±0) Sets the B gamma level.
Gamma
Category
Original / STD / HG / S-Log3 Selects original gamma (Original),
standard gamma (STD), hypergamma
(HG), or S-Log3.
Paint >Gamma
Sets gamma correction settings.
Item Sub-item setting Description
Gamma
Select
When Gamma Category is set to STD:
STD1 DVW / STD2 ×4.5 / STD3 ×3.5 /
STD4 240M / STD5 R709 / STD6 ×5.0
When Gamma Category is set to HG:
HG1 3250G36 / HG2 4600G30 /
HG3 3259G40 / HG4 4609G33 /
HG7 8009G40 / HG8 8009G33
When Gamma Category is set to S-Log3:
S-Log3
When Gamma Category is set to Original:
S-Cinetone
Selects the gamma table used for
gamma correction.
See the table below for details about
hypergamma and S-Log3.
Name Dynamic
range
White
limit
18% gray
card video
output (20%
video input)
HG1 3250G36 325% 100% 36%
HG2 4600G30 460% 100% 30%
HG3 3259G40 325% 109% 40%
HG4 4609G33 460% 109% 33%
HG7 8009G40 800% 109% 40%
HG8 8009G33 800% 109% 33%
S-Log3 1300% 41%
Paint >Black Gamma
Sets black gamma correction settings.
Item Sub-item setting Description
Setting On / Off Turns the black gamma correction
function on/off.
(Enabled when Gamma >Gamma
Category is set to STD)
[Note]
The Black Gamma and Knee >Knee Saturation
functions cannot be used at the same time.
Range Low / L.Mid / H.Mid Selects the effective range of the black
gamma correction.
Master Black
Gamma
–99 to +99 (±0) Sets the master black gamma level.