16
G. Auto-Sleep Mode (Hot Air Gun)
The device has a built-in auto-sleep mode feature such that if the
Hot Air Gun sits on its handle and remained idle after a certain period
the prefix of the display for Hot Air Gun air temperature will also change
from C to d) , the device will switch to sleep mode. This mechanism
is triggered by a countdown timer. When the timer has elapsed, the
system will blow air (at room temperature) at maximum rate in order to
bring down the temperature. During this time, the Hot Air Gun air level
display will change to cool. Once the temperature drops to
approximately 90°C, the Hot Air Gun will automatically stop and show
four dashes - - - - indicating that the system is now in sleep mode.
To reactivate the hot air gun simply press pick up the hot air gun from
its dock.
Changing SLEEP Mode Timer (HOT AIR GUN)
By default, the system has 15-minute countdown time before the
hot air gun goes to sleep mode. This can be altered by the following
procedure.
1. While the hot air gun is on stand-by mode (0FF is displayed on
the panels 18 and 16), Press and hold the UP button of the
HOT AIR GUN AIRFLOW adjustment button(3 control panel) .
2. Wait until 015d is displayed on the Hot Air Gun Temperature
display panel, 18.
3. Release the button when 005d appears.
4. Adjust the time using the UP and DOWN buttons of the HOT AIR
GUN TEMPERATURE adjustment buttons (2 control panel).
5. Confirm the change by pressing and holding the DOWN button of
the HOT AIR GUN AIRFLOW adjustment button. (3 from control
panel guide)
6. The system will switch back to displaying OFF indicating the
new sleep timer is saved into the system.
OPERATING GUIDELINES
13
E. DESOLDERING GUN
1. Connect the De-soldering gun connection assembly to the 6-pin
receptacle located at the front of the control panel (“9” from the
CONTROL PANEL GUIDE).
2. Follow the initial procedures (“A. INITIAL PROCEDURES”).
3. Connect the vacuum tube to the Smoke Absorber Terminal or
Vacuum Cap (“7” from the control panel).
4. Activate the “DESOLDER GUNActivation switch (“12” from control
panel). This will automatically start to increase the temperature of
the desoldering gun to 350°C (default).
5. Adjust the desoldering gun temp. using the DESOLDER
TEMPERATURE ADJUSTMENT buttons (“5” from the control panel).
6. Allow the desoldering gun's tip and its barrel to heat up. Tip
temperature can be reached within 5-6 minutes and its barrel would
obtain optimum temperature 5-9 minutes after the tip temperature
has been reached. If upon initial use solder gets stuck at the end of
the barrel, clean the barrel and wait a few more minutes for the
barrel to heat up.
7. Check the tip temperature with an external temperature sensor,
adjust temperature settings higher or lower for the right
temperature. Or recalibrate at the desired temperature level
8. Ensure that all the solder is melted before triggering the pump.
(Partially melted solder will still be sucked up however it would clog
the barrel).