Changing SLEEP Timer (Desoldering Gun)
By default, the systems sleep duration is 0 indicating the sleep
timer is disabled. To activate the sleep function follow the procedures.
1. Turn off the Soldering Iron Function switch (14 from the
control panel) .Ensure that the Desoldering Gun Function
switch is in the off position(12 from the control panel) .
2. Press and hold the DOWN button of the Soldering Iron
Temperature Adjustment button (4 from the control panel) .
3. The Desoldering Gun Temperature Display (14 from the
control panel) . Will switch to 000t indicating it is now in the
desoldering gun sleep timer adjustment mode. Release the
DOWN button of the Soldering Iron Temperature Adjustment
button
4. Use the Desoldering Gun Temperature Adjustment buttons (5
from the control panel) to increase or decrease the sleep
duration. Timer is adjustable from 1 to 60 minutes, a value of 0
indicates that the sleep timer function is turned off.
5. Confirm the change by pressing and holding the UP button of
the Soldering Iron Temperature Adjustment button (4 from
the control panel).
OPERATING GUIDELINES
11
To start the automated reworking function, Follow the guide
below:
1. Ensure that the hot air gun function switch is deactivated.
2. Press the Hot Air Gun Automate Function Selector (“17” from the
control panel) until the display shows “run”.
3. Press the up button of the Hot Air Gun Temperature Adjustment
Button to initiate the automated reworking function.
Upon the start of the automated reworking function the hot air gun
would slowly heat up until it reaches the set temperature of segment A.
After the set temperature is reached it would maintain the set
temperature for the duration as set in segment A. The displayed
duration will start counting down until the timer reaches 0 after which it
will proceed to the next segment, repeating the process until it finishes
all 5 segments. Upon the end of the fifth segment the cool down
function will be activated to automatically cool down the system before
shutting off
NOTES:
1. Hot Air Gun Temperature is adjustable between 100° and 480°C .
2. Hot Air Gun Airflow Rate is adjustable between 15 and 100.
3. The hot air gun is equipped with a temperature limiting feature to
only allow a temperature rise of 3 degrees per second. This is in ac-
cordance with the industry standard allowable temperature rise time
to prevent damage to sensitive components.
OPERATING GUIDELINES
Loading ...
Loading ...
Loading ...